DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Chankyu | - |
dc.contributor.author | Yoo, Hyunjun | - |
dc.contributor.author | Kim, Yewon | - |
dc.contributor.author | Moon, Myungkook | - |
dc.contributor.author | Kim, Jong Yul | - |
dc.contributor.author | Kang, Dong Uk | - |
dc.contributor.author | Lee, Daehee | - |
dc.contributor.author | Kim, Myung Soo | - |
dc.contributor.author | Cho, Minsik | - |
dc.contributor.author | Lee, Eunjoong | - |
dc.contributor.author | Cho, Gyuseong | - |
dc.date.accessioned | 2017-03-31T05:42:28Z | - |
dc.date.available | 2017-03-31T05:42:28Z | - |
dc.date.created | 2017-03-20 | - |
dc.date.issued | 2016-09 | - |
dc.identifier.citation | RADIATION PROTECTION DOSIMETRY, v.170, no.1-4, pp.377 - 381 | - |
dc.identifier.issn | 0144-8420 | - |
dc.identifier.uri | http://hdl.handle.net/10203/222841 | - |
dc.description.abstract | Plastic scintillation detectors have practical advantages in the field of dosimetry. Energy calibration of measured gamma spectra is important for dose computation, but it is not simple in the plastic scintillators because of their different characteristics and a finite resolution. In this study, the gamma spectra in a polystyrene scintillator were calculated for the energy calibration and dose computation. Based on the relationship between the energy resolution and estimated energy broadening effect in the calculated spectra, the gamma spectra were simply calculated without many iterations. The calculated spectra were in agreement with the calculation by an existing method and measurements. | - |
dc.language | English | - |
dc.publisher | OXFORD UNIV PRESS | - |
dc.subject | RAYS | - |
dc.title | CALCULATION OF GAMMA SPECTRA IN A PLASTIC SCINTILLATOR FOR ENERGY CALIBRATION AND DOSE COMPUTATION | - |
dc.type | Article | - |
dc.identifier.wosid | 000384713300085 | - |
dc.identifier.scopusid | 2-s2.0-84992511249 | - |
dc.type.rims | ART | - |
dc.citation.volume | 170 | - |
dc.citation.issue | 1-4 | - |
dc.citation.beginningpage | 377 | - |
dc.citation.endingpage | 381 | - |
dc.citation.publicationname | RADIATION PROTECTION DOSIMETRY | - |
dc.identifier.doi | 10.1093/rpd/ncw086 | - |
dc.contributor.localauthor | Kim, Chankyu | - |
dc.contributor.localauthor | Yoo, Hyunjun | - |
dc.contributor.localauthor | Kim, Yewon | - |
dc.contributor.localauthor | Kang, Dong Uk | - |
dc.contributor.localauthor | Lee, Daehee | - |
dc.contributor.localauthor | Kim, Myung Soo | - |
dc.contributor.localauthor | Cho, Minsik | - |
dc.contributor.localauthor | Lee, Eunjoong | - |
dc.contributor.localauthor | Cho, Gyuseong | - |
dc.contributor.nonIdAuthor | Moon, Myungkook | - |
dc.contributor.nonIdAuthor | Kim, Jong Yul | - |
dc.type.journalArticle | Article | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.