A Mouse With Two Optical Sensors That Eliminates Coordinate Disturbance During Skilled Strokes

Cited 9 time in webofscience Cited 0 time in scopus
  • Hit : 577
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Byungjooko
dc.contributor.authorBang, Hyunwooko
dc.date.accessioned2016-11-09T08:29:14Z-
dc.date.available2016-11-09T08:29:14Z-
dc.date.created2016-11-03-
dc.date.created2016-11-03-
dc.date.issued2015-03-
dc.identifier.citationHUMAN-COMPUTER INTERACTION, v.30, no.2, pp.122 - 155-
dc.identifier.issn0737-0024-
dc.identifier.urihttp://hdl.handle.net/10203/214014-
dc.description.abstractThe computer mouse is rarely used for drawing due to its body-fixed coordinate system, which creates a stroke that differs from the user's original hand movement. In this study, we resolve this problem by implementing a new mouse called StereoMouse, which eliminates the rotational disturbance of the coordinate system in real-time. StereoMouse is a special mouse with two optical sensors, and its coordinate orientation at the beginning of a stroke is maintained throughout the movement by measuring and compensating for the angular deviation estimated from those sensors. The drawing performance of StereoMouse was measured by means of having users perform the task of repeatedly drawing a basic shape. The results of this experiment showed that StereoMouse eliminated the horizontal drift typically observed in a stroke drawn by a normal mouse. Consequently, StereoMouse allowed the users to draw shapes at a 10.6% faster mean speed with a 10.4% shorter travel time than a normal mouse would. Furthermore, StereoMouse showed 37.1% lower chance of making incorrect gesture input than the normal mouse-
dc.languageEnglish-
dc.publisherTAYLOR & FRANCIS INC-
dc.subjectCOMPUTER MOUSE-
dc.subjectCURSOR TRAJECTORIES-
dc.subjectPOSITIONING MOVEMENTS-
dc.subjectHUMAN ARM-
dc.subjectDESIGN-
dc.subjectORIENTATION-
dc.subjectPRESSURE-
dc.subjectTOUCHPAD-
dc.subjectTASKS-
dc.subjectTIME-
dc.titleA Mouse With Two Optical Sensors That Eliminates Coordinate Disturbance During Skilled Strokes-
dc.typeArticle-
dc.identifier.wosid000345228500002-
dc.identifier.scopusid2-s2.0-84912115478-
dc.type.rimsART-
dc.citation.volume30-
dc.citation.issue2-
dc.citation.beginningpage122-
dc.citation.endingpage155-
dc.citation.publicationnameHUMAN-COMPUTER INTERACTION-
dc.identifier.doi10.1080/07370024.2014.894888-
dc.contributor.localauthorLee, Byungjoo-
dc.contributor.nonIdAuthorBang, Hyunwoo-
dc.type.journalArticleArticle-
dc.subject.keywordPlusCOMPUTER MOUSE-
dc.subject.keywordPlusCURSOR TRAJECTORIES-
dc.subject.keywordPlusPOSITIONING MOVEMENTS-
dc.subject.keywordPlusHUMAN ARM-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusORIENTATION-
dc.subject.keywordPlusPRESSURE-
dc.subject.keywordPlusTOUCHPAD-
dc.subject.keywordPlusTASKS-
dc.subject.keywordPlusTIME-
Appears in Collection
GCT-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 9 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0