A top-crossover-to-bottom addressed segmented annular array using piezoelectric micromachined ultrasonic transducers

Cited 12 time in webofscience Cited 9 time in scopus
  • Hit : 530
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorJung, Joontaekko
dc.contributor.authorLee, Wonjunko
dc.contributor.authorKang, Woojinko
dc.contributor.authorHong, Hyeryungko
dc.contributor.authorSong, Hi Yuenko
dc.contributor.authorOh, Inn-Yealko
dc.contributor.authorPark, Chul Soonko
dc.contributor.authorChoi, Hongsooko
dc.date.accessioned2016-06-07T09:15:30Z-
dc.date.available2016-06-07T09:15:30Z-
dc.date.created2016-01-19-
dc.date.created2016-01-19-
dc.date.issued2015-11-
dc.identifier.citationJOURNAL OF MICROMECHANICS AND MICROENGINEERING, v.25, no.11-
dc.identifier.issn0960-1317-
dc.identifier.urihttp://hdl.handle.net/10203/207847-
dc.description.abstractWe design and fabricate segmented annular arrays (SAAs) using piezoelectric micromachined ultrasonic transducers (pMUTs) to demonstrate the feasibility of acoustic focusing of ultrasound. The fabricated SAAs have 25 concentric top-electrode signal lines and eight bottom-electrodes for grounding to enable electronic steering of selectively grouped ultrasonic transducers from 2393 pMUT elements. Each element in the array is connected by top-crossover- to-bottom metal bridges, which reduce the parasitic capacitance. Circular-shaped pMUT elements, 120 mu m in diameter, are fabricated using 1 mu m-thick sol-gel lead zirconate titanate on a silicon wafer. To utilize the high-density pMUT array, a deep reactive ion etching process is used for anisotropic silicon etching to realize the transducer membranes. The resonant frequency and effective coupling coefficient of the elements, measured with an impedance analyzer, yields 1.517 MHz and 1.29%, respectively, in air. The SAAs using pMUTs are packaged on a printed circuit board and coated with parylene C for acoustic intensity measurements in water. The ultrasound generated by each segmented array is focused on a selected point in space. When a 5 V-pp, 1.5 MHz square wave is applied, the maximum spatial peak temporal average intensity (I-spta) is found to be 79 mW cm(-2) 5 mm from the SAAs' surface without beamforming. The beam widths (-3 dB) of ultrasonic radiation patterns in the elevation and azimuth directions are recorded as 3 and 3.4 mm, respectively. The results successfully show the feasibility of focusing ultrasound on a small area with SAAs using pMUTs.-
dc.languageEnglish-
dc.publisherIOP PUBLISHING LTD-
dc.subjectHIGH-FREQUENCY ULTRASOUND-
dc.subjectCMUT ARRAYS-
dc.subjectDESIGN-
dc.subjectFABRICATION-
dc.titleA top-crossover-to-bottom addressed segmented annular array using piezoelectric micromachined ultrasonic transducers-
dc.typeArticle-
dc.identifier.wosid000366862100027-
dc.identifier.scopusid2-s2.0-84946029627-
dc.type.rimsART-
dc.citation.volume25-
dc.citation.issue11-
dc.citation.publicationnameJOURNAL OF MICROMECHANICS AND MICROENGINEERING-
dc.identifier.doi10.1088/0960-1317/25/11/115024-
dc.contributor.localauthorPark, Chul Soon-
dc.contributor.nonIdAuthorJung, Joontaek-
dc.contributor.nonIdAuthorLee, Wonjun-
dc.contributor.nonIdAuthorKang, Woojin-
dc.contributor.nonIdAuthorHong, Hyeryung-
dc.contributor.nonIdAuthorSong, Hi Yuen-
dc.contributor.nonIdAuthorChoi, Hongsoo-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorsegmented annular arrays-
dc.subject.keywordAuthorpiezoelectric micromachined ultrasonic transducers (pMUTs)-
dc.subject.keywordAuthorultrasonic intensity-
dc.subject.keywordAuthorMEMS-
dc.subject.keywordPlusHIGH-FREQUENCY ULTRASOUND-
dc.subject.keywordPlusCMUT ARRAYS-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusFABRICATION-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 12 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0