Co-60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications

Cited 1 time in webofscience Cited 2 time in scopus
  • Hit : 253
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorSHIN, Goo-Hwanko
dc.date.accessioned2016-04-06T01:25:26Z-
dc.date.available2016-04-06T01:25:26Z-
dc.date.created2015-04-10-
dc.date.created2015-04-10-
dc.date.created2015-04-10-
dc.date.issued2014-11-
dc.identifier.citationJOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, v.9, no.6, pp.2065 - 2069-
dc.identifier.issn1975-0102-
dc.identifier.urihttp://hdl.handle.net/10203/202946-
dc.description.abstractThe DAC-7512E is a 12-bit digital to analog converter that is low power and a single package with internal buffers. The DAC-7512E takes up minimal PCB area for applications of space power electronics design. The spacecraft mass is a crucial point considering spacecraft launch into space. Therefore, we have performed a TID test for the DAC-7512E 12-bit serial input digital to analog converter to reduce the spacecraft mass by using a low-level Gamma-ray irradiator with Co-60 gamma-ray sources. The irradiation with Co-60 gamma-rays was carried out at doses from 0 krad to 100 had to check the error status of the device in terms of current, voltage and bit error status during conversion. The DAC-7512E 12-bit serial digital to analog converter should work properly from 0 had to 30 had without any error.-
dc.languageEnglish-
dc.publisherKOREAN INST ELECTR ENG-
dc.subjectSYSTEMS-
dc.subjectMEMORY-
dc.subjectCELLS-
dc.titleCo-60 Gamma-Ray Effects on the DAC-7512E 12-Bit Serial Digital to Analog Converter for Space Power Applications-
dc.typeArticle-
dc.identifier.wosid000344040500034-
dc.identifier.scopusid2-s2.0-84908539539-
dc.type.rimsART-
dc.citation.volume9-
dc.citation.issue6-
dc.citation.beginningpage2065-
dc.citation.endingpage2069-
dc.citation.publicationnameJOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY-
dc.identifier.doi10.5370/JEET.2014.9.6.2065-
dc.contributor.localauthorSHIN, Goo-Hwan-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorSpace power electronics-
dc.subject.keywordAuthorTotal ionizing dose-
dc.subject.keywordAuthorDigital to analog converter-
dc.subject.keywordAuthorData conversion-
dc.subject.keywordAuthorCo-60 gamma-ray-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordPlusMEMORY-
dc.subject.keywordPlusCELLS-
Appears in Collection
RIMS Journal Papers
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 1 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0