dc.description.abstract | SIGMA CP (Simulant Internal Gravitated Material Apparatus Circular Pool) tests were performed to study natural convection characterized by a high modified Rayleigh number (Ra') in a semicircular pool. The test apparatus had a 500 mm diameter, 250 mm height and 100 mm width. Two thin cartridge heaters, which had a sheath diameter of 6 mm and a length of 2000 mm, were used to simulate internal heating in the pool. They were uniformly distributed in the semicircular pool to supply a maximum heating power of 3 kW to the pool. The Ra' was varied from 10(6) to 10(11) based on the power input. The working fluid Prandtl number (Pr) ranged between 4 and 8 for water and was 0.7 for air. Particular attention was paid to the influence of Pr on the natural convection heat transfer in the pool. A number of relations between the Nusselt number (Nu) and Ra' were determined for the boundary conditions in the semicircular pool. The boundary condition is that the upper and lower walls are cooled isothermally. The experimental results indicated that both the upward and downward natural convection heat transfer rates were affected by Pr. The Rayleigh numbers were determined up to 7 x 10(11) from this test. The resultant engineering correlations can be applied to simulations of a spectrum of loss-of-coolant accidents to determine the reactor vessel failure time. | - |
dc.language | English | - |
dc.publisher | PERGAMON-ELSEVIER SCIENCE LTD | - |
dc.subject | HORIZONTAL FLUID LAYER | - |
dc.subject | ENERGY-SOURCES | - |
dc.title | Experimental study of natural convection heat transfer in a volumetrically heated semicircular pool | - |
dc.type | Article | - |
dc.identifier.wosid | 000342248400044 | - |
dc.identifier.scopusid | 2-s2.0-84905562776 | - |
dc.type.rims | ART | - |
dc.citation.volume | 73 | - |
dc.citation.beginningpage | 432 | - |
dc.citation.endingpage | 440 | - |
dc.citation.publicationname | ANNALS OF NUCLEAR ENERGY | - |
dc.identifier.doi | 10.1016/j.anucene.2014.07.019 | - |
dc.contributor.localauthor | Lee, Kun Jai | - |
dc.contributor.localauthor | Yun, Jong-Il | - |
dc.contributor.nonIdAuthor | Suh, Kune Y. | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | Natural convection | - |
dc.subject.keywordAuthor | Semicircular pool | - |
dc.subject.keywordAuthor | Rayleigh number | - |
dc.subject.keywordAuthor | Prandtl number | - |
dc.subject.keywordAuthor | Nusselt number | - |
dc.subject.keywordAuthor | Severe accident | - |
dc.subject.keywordPlus | HORIZONTAL FLUID LAYER | - |
dc.subject.keywordPlus | ENERGY-SOURCES | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.