Fourier analysis of the imaging characteristics of a CMOS active pixel detector for mammography by using a linearization method

Cited 5 time in webofscience Cited 5 time in scopus
  • Hit : 331
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorHan, Jong Chulko
dc.contributor.authorYun, Seungmanko
dc.contributor.authorYoun, Hanbeanko
dc.contributor.authorKam, Soohwako
dc.contributor.authorCho, Seungryongko
dc.contributor.authorAchterkirchen, Thorsten G.ko
dc.contributor.authorKim, Ho Kyungko
dc.date.accessioned2015-11-20T09:52:47Z-
dc.date.available2015-11-20T09:52:47Z-
dc.date.created2014-10-27-
dc.date.created2014-10-27-
dc.date.issued2014-09-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.65, no.5, pp.770 - 777-
dc.identifier.issn0374-4884-
dc.identifier.urihttp://hdl.handle.net/10203/201153-
dc.description.abstractActive pixel design using the complementary metal-oxide-semiconductor (CMOS) process is a compelling solution for use in X-ray imaging detectors because of its excellent electronic noise characteristics. We have investigated the imaging performance of a CMOS active pixel photodiode array coupled to a granular phosphor through a fiber-optic faceplate for mammographic applications. The imaging performance included the modulation-transfer function (MTF), noise-power spectrum (NPS), and detective quantum efficiency (DQE). Because we observed a nonlinear detector response at low exposures, we used the linearization method for the analysis of the DQE. The linearization method uses the images obtained at detector input, which are converted from those obtained at detector output by using the inverse of the detector response. Compared to the conventional method, the linearization method provided almost the same MTF and a slightly lower normalized NPS. However, the difference between the DQE results obtained by using the two methods was significant. We claim that the conventional DQE analysis of a detector having a nonlinear response characteristic can yield wrong results. Under the standard mammographic imaging condition, we obtained a DQE performance that was competitive with the performances of conventional flat-panel mammography detectors. We believe that the CMOS detector investigated in this study can be successfully used for mammography.-
dc.languageEnglish-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectDIGITAL RADIOGRAPHY DETECTORS-
dc.subjectPHOTODIODE-ARRAY DETECTORS-
dc.subjectX-RAY-DETECTOR-
dc.subjectPERFORMANCE-
dc.subjectSENSOR-
dc.subjectSCINTILLATOR-
dc.subjectRESOLUTION-
dc.subjectPHOSPHORS-
dc.subjectSYSTEM-
dc.subjectIMAGER-
dc.titleFourier analysis of the imaging characteristics of a CMOS active pixel detector for mammography by using a linearization method-
dc.typeArticle-
dc.identifier.wosid000342449400030-
dc.identifier.scopusid2-s2.0-84907668979-
dc.type.rimsART-
dc.citation.volume65-
dc.citation.issue5-
dc.citation.beginningpage770-
dc.citation.endingpage777-
dc.citation.publicationnameJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.identifier.doi10.3938/jkps.65.770-
dc.contributor.localauthorCho, Seungryong-
dc.contributor.nonIdAuthorHan, Jong Chul-
dc.contributor.nonIdAuthorYun, Seungman-
dc.contributor.nonIdAuthorYoun, Hanbean-
dc.contributor.nonIdAuthorKam, Soohwa-
dc.contributor.nonIdAuthorAchterkirchen, Thorsten G.-
dc.contributor.nonIdAuthorKim, Ho Kyung-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorDigital mammography-
dc.subject.keywordAuthorCMOS-
dc.subject.keywordAuthorMTF-
dc.subject.keywordAuthorNPS-
dc.subject.keywordAuthorDQE-
dc.subject.keywordAuthorNonlinear response-
dc.subject.keywordAuthorLinearization-
dc.subject.keywordPlusDIGITAL RADIOGRAPHY DETECTORS-
dc.subject.keywordPlusPHOTODIODE-ARRAY DETECTORS-
dc.subject.keywordPlusX-RAY-DETECTOR-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusSCINTILLATOR-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordPlusPHOSPHORS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusIMAGER-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0