Improving the extraction of headspace volatile compounds: development of a headspace multi-temperature solid-phase micro-extraction-single shot-gas chromatography/mass spectrometry (mT-HSSPME-ss-GC/MS) method and application to characterization of ground coffee aroma

Cited 8 time in webofscience Cited 9 time in scopus
  • Hit : 421
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLee, Chang Gookko
dc.contributor.authorLee, Younghoonko
dc.contributor.authorLee, Jae-Gonko
dc.contributor.authorBuglass, Alan Jko
dc.date.accessioned2015-05-22T02:27:46Z-
dc.date.available2015-05-22T02:27:46Z-
dc.date.created2015-05-20-
dc.date.created2015-05-20-
dc.date.issued2015-05-
dc.identifier.citationANALYTICAL METHODS, v.7, no.8, pp.3521 - 3536-
dc.identifier.issn1759-9660-
dc.identifier.urihttp://hdl.handle.net/10203/198585-
dc.description.abstractA multi-temperature headspace solid-phase micro-extraction-single shot-gas chromatography/mass spectrometry (mT-HSSPME-ss-GC/MS) method has been developed for headspace analysis. Three SPME fibers (50/30 mm DVB/CAR/PDMS) were used simultaneously for the extraction of volatile components from the headspace of a sample in three sample chambers at three different temperatures. A cryofocusing technique was adopted to avoid peak broadening and to maximize resolution during the sequential thermal desorption of the SPME fibers prior to a 'single-shot' chromatographic run. The method was developed and validated on a model ethanolic flavor mixture, containing 81 components. Comparison of mT-HSSPME-ss-GC/MS (10 min incubation time, then 30 min extraction time at 22, 50, and 70 degrees C extraction temperatures) with conventional SPME-GC/MS at a fixed temperature of 22, 50, or 70 degrees C showed that the former gave a headspace GC profile of the flavor mixture that was much closer to that of the syringe (direct) injection profile. None of the conventional headspace SPME extraction profiles were a good match to the syringe injection profile. The same technique applied to the headspace of coffee grounds gave a plentiful headspace volatile component profile compared to that of a single SPME analysis at a fixed single extraction temperature (22, 50, and 70 degrees C). The average percent recovery (defined for each component as 100 x mT-SPME (22 degrees C + 50 degrees C + 70 degrees C) TIC peak intensity divided by the arithmetic sum of individual temperature SPME (22 degrees C, 50 degrees C, 70 degrees C) TIC peak intensities) was 89.8% and 132 components were detected by mT-SPME-ss-GC/MS in the headspace of coffee grounds.-
dc.languageEnglish-
dc.publisherROYAL SOC CHEMISTRY-
dc.subjectROASTING PROCESS-
dc.subjectMICROEXTRACTION-
dc.subjectPROFILE-
dc.subjectFIBERS-
dc.subjectTEMPERATURES-
dc.subjectFLAVOR-
dc.subjectBREWS-
dc.subjectSBSE-
dc.subjectMS-
dc.titleImproving the extraction of headspace volatile compounds: development of a headspace multi-temperature solid-phase micro-extraction-single shot-gas chromatography/mass spectrometry (mT-HSSPME-ss-GC/MS) method and application to characterization of ground coffee aroma-
dc.typeArticle-
dc.identifier.wosid000352897500030-
dc.identifier.scopusid2-s2.0-84928027341-
dc.type.rimsART-
dc.citation.volume7-
dc.citation.issue8-
dc.citation.beginningpage3521-
dc.citation.endingpage3536-
dc.citation.publicationnameANALYTICAL METHODS-
dc.identifier.doi10.1039/c4ay03034f-
dc.contributor.localauthorLee, Younghoon-
dc.contributor.localauthorBuglass, Alan J-
dc.contributor.nonIdAuthorLee, Jae-Gon-
dc.type.journalArticleArticle-
dc.subject.keywordPlusROASTING PROCESS-
dc.subject.keywordPlusMICROEXTRACTION-
dc.subject.keywordPlusPROFILE-
dc.subject.keywordPlusFIBERS-
dc.subject.keywordPlusTEMPERATURES-
dc.subject.keywordPlusFLAVOR-
dc.subject.keywordPlusBREWS-
dc.subject.keywordPlusSBSE-
dc.subject.keywordPlusMS-
Appears in Collection
CH-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 8 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0