Differential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube

Cited 4 time in webofscience Cited 4 time in scopus
  • Hit : 340
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorYoon, Kwon-Hako
dc.contributor.authorRyu, Jong Hyunko
dc.contributor.authorJung, Chang Wonko
dc.contributor.authorRyu, Cheol Wooko
dc.contributor.authorKim, Young Joko
dc.contributor.authorKwon, Young Manko
dc.contributor.authorPark, Miranko
dc.contributor.authorCho, Seungryongko
dc.contributor.authorChon, Kwon Suko
dc.date.accessioned2015-04-07T04:50:24Z-
dc.date.available2015-04-07T04:50:24Z-
dc.date.created2015-02-09-
dc.date.created2015-02-09-
dc.date.issued2014-12-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.65, no.12, pp.2111 - 2116-
dc.identifier.issn0374-4884-
dc.identifier.urihttp://hdl.handle.net/10203/195219-
dc.description.abstractX-ray phase-contrast imaging can provide images with much greater soft-tissue contrast than conventional absorption-based images. In this paper, we describe differential X-ray phase-contrast images of insect specimens that were obtained using a grating-based Talbot interferometer and a laboratory X-ray source with a spot size of a few tens of micrometers. We developed the interferometer on the basis of the wavelength, periods, and height of the gratings; the field of view depends on the size of the grating, considering the refractive index of the specimen. The phase-contrast images were acquired using phase-stepping methods. The phase contrast imaging provided a significantly enhanced soft-tissue contrast compared with the attenuation data. The contour of the sample was clearly visible because the refraction from the edges of the object was strong in the differential phase-contrast image. Our results demonstrate that a grating-based Talbot interferometer with a conventional X-ray tube may be attractive as an X-ray imaging system for generating phase images. X-ray phase imaging obviously has sufficient potential and is expected to soon be a great tool for medical diagnostics.-
dc.languageEnglish-
dc.publisherKOREAN PHYSICAL SOC-
dc.subjectFABRICATION-
dc.titleDifferential X-ray phase-contrast imaging with a grating interferometer using a laboratory X-ray micro-focus tube-
dc.typeArticle-
dc.identifier.wosid000347455600020-
dc.identifier.scopusid2-s2.0-84920438251-
dc.type.rimsART-
dc.citation.volume65-
dc.citation.issue12-
dc.citation.beginningpage2111-
dc.citation.endingpage2116-
dc.citation.publicationnameJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.identifier.doi10.3938/jkps.65.2111-
dc.contributor.localauthorCho, Seungryong-
dc.contributor.nonIdAuthorYoon, Kwon-Ha-
dc.contributor.nonIdAuthorRyu, Jong Hyun-
dc.contributor.nonIdAuthorJung, Chang Won-
dc.contributor.nonIdAuthorRyu, Cheol Woo-
dc.contributor.nonIdAuthorKim, Young Jo-
dc.contributor.nonIdAuthorKwon, Young Man-
dc.contributor.nonIdAuthorChon, Kwon Su-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorX-ray phase contrast image-
dc.subject.keywordAuthorTalbot interferometer-
dc.subject.keywordAuthorPhase stepping-
dc.subject.keywordAuthorDiffraction grating-
dc.subject.keywordPlusFABRICATION-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0