Real-time detection of an airborne microorganism using inertial impaction and mini-fluorescent microscopy

Cited 27 time in webofscience Cited 25 time in scopus
  • Hit : 555
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKang, Joon Sangko
dc.contributor.authorLee, Kang-Sooko
dc.contributor.authorKim, Sang Sooko
dc.contributor.authorBae, Gwi Namko
dc.contributor.authorJung, Jae Heeko
dc.date.accessioned2015-04-06T08:01:53Z-
dc.date.available2015-04-06T08:01:53Z-
dc.date.created2013-11-11-
dc.date.created2013-11-11-
dc.date.created2013-11-11-
dc.date.issued2014-
dc.identifier.citationLAB ON A CHIP, v.14, no.1, pp.244 - 251-
dc.identifier.issn1473-0197-
dc.identifier.urihttp://hdl.handle.net/10203/194891-
dc.description.abstractTo achieve successful real-time detection of airborne pathogenic microorganisms, the problem must be considered in terms of their physical size and biological characteristics. We developed an airborne microorganism detection chip to realize the detection of microorganisms, ensuring compactness, sensitivity, cost-efficiency, and portability, using three key components: an inertial impaction system, a cartridge-type impaction plate, and a mini-fluorescent microscope. The inertial impaction system was used to separate microorganisms in terms of their aerodynamic particle size, and was fabricated with three impaction stages. Numerical analysis was performed to design the system; the calculated cutoff diameter at each impaction stage was 2.02 (first stage), 0.88 (second stage), and 0.54 mu m (third stage). The measured cutoff diameters were 2.24, 0.91, and 0.49 mu m, respectively. A cartridge-type impaction plate was used, composed of molded polydimethylsiloxane (PDMS) and an actual impaction region made of a SYBR green I dye-stained agar plate. A mini-fluorescent microscope was used to distinguish microbes from non-biological particles. Images of the microorganisms deposited at the impaction zone were obtained via mini-fluorescent microscopy, and fluorescent intensities of the images were calculated using in-house image-processing software. The results showed that the developed system successfully identified aerosolized biological particles from non-biological particles in real time-
dc.languageEnglish-
dc.publisherROYAL SOC CHEMISTRY-
dc.titleReal-time detection of an airborne microorganism using inertial impaction and mini-fluorescent microscopy-
dc.typeArticle-
dc.identifier.wosid000327669000027-
dc.identifier.scopusid2-s2.0-84888985591-
dc.type.rimsART-
dc.citation.volume14-
dc.citation.issue1-
dc.citation.beginningpage244-
dc.citation.endingpage251-
dc.citation.publicationnameLAB ON A CHIP-
dc.identifier.doi10.1039/C3LC50805F-
dc.contributor.localauthorKang, Joon Sang-
dc.contributor.localauthorKim, Sang Soo-
dc.contributor.nonIdAuthorBae, Gwi Nam-
dc.contributor.nonIdAuthorJung, Jae Hee-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordPlusPOLYMERASE-CHAIN-REACTION-
dc.subject.keywordPlusCASCADE IMPACTOR-
dc.subject.keywordPlusPCR-
dc.subject.keywordPlusBACTERIA-
dc.subject.keywordPlusCELLS-
dc.subject.keywordPlusQUANTIFICATION-
dc.subject.keywordPlusBIOAEROSOLS-
dc.subject.keywordPlusEXPOSURE-
dc.subject.keywordPlusVIRUSES-
dc.subject.keywordPlusDESIGN-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 27 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0