Development of Filtering Methods for PET Signals Contaminated by RF Pulses for Combined PET-MRI

Cited 5 time in webofscience Cited 4 time in scopus
  • Hit : 276
  • Download : 182
DC FieldValueLanguage
dc.contributor.authorHuh, Yoonsukko
dc.contributor.authorChoi, Yongko
dc.contributor.authorHong, Key Joko
dc.contributor.authorHu, Weiko
dc.contributor.authorKang, Jihoonko
dc.contributor.authorJung, Jin Hoko
dc.contributor.authorSong, Myung Sungko
dc.contributor.authorPark, HyunWookko
dc.contributor.authorKim, Byung-Taeko
dc.date.accessioned2014-08-28T08:28:05Z-
dc.date.available2014-08-28T08:28:05Z-
dc.date.created2013-11-11-
dc.date.created2013-11-11-
dc.date.issued2013-10-
dc.identifier.citationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.60, no.5, pp.3205 - 3211-
dc.identifier.issn0018-9499-
dc.identifier.urihttp://hdl.handle.net/10203/188536-
dc.description.abstractThis paper presents the development of filtering methods for positron emission tomography (PET) signals contaminated by radio frequency (RF) pulses for combined PET and clinical 3-T magnetic resonance imaging (MRI). The filtering methods include software, hardware, and hybrid correction methods. In the software correction method, PET signals are assessed, and valid signals are identified based on the characteristics of a typical PET signal using Field-Programmable Gate Array (FPGA)-based programming. The hardware correction method makes use of differential-to-single-ended and low-pass filter circuits for PET analog signals. The hybrid correction method involves the sequential application of both the hardware and software methods. Both valid and contaminated PET signals are measured with an oscilloscope. An evaluation is then made of the performance (energy resolution, photopeak channel, total counts, and coincidence timing resolution) of the PET detector modules with and without various MR sequences (gradient echo, spin echo T1 sequence). For all correction methods, the energy resolution, photopeak position, and coincidence timing resolution with MR sequences are similar (< 3%) to those without MR sequences. However, the total count of each module depends greatly on the method applied. The hybrid correction method displays an ability to preserve (< 1%) the total counts of the modules during various MR sequences. The results show that this filtering method, which can reject noise signals and reduce count loss while preserving the valid analog signals of MR sequences, is reliable and useful for the development of simultaneous PET-MRI.-
dc.languageEnglish-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectPET/MRI SYSTEM-
dc.subjectCOMPATIBLE PET-
dc.subjectACQUISITION-
dc.subjectARTIFACTS-
dc.subjectDETECTOR-
dc.subjectSCANNER-
dc.titleDevelopment of Filtering Methods for PET Signals Contaminated by RF Pulses for Combined PET-MRI-
dc.typeArticle-
dc.identifier.wosid000325827200006-
dc.identifier.scopusid2-s2.0-84885953184-
dc.type.rimsART-
dc.citation.volume60-
dc.citation.issue5-
dc.citation.beginningpage3205-
dc.citation.endingpage3211-
dc.citation.publicationnameIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.identifier.doi10.1109/TNS.2013.2274075-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorPark, HyunWook-
dc.contributor.nonIdAuthorHuh, Yoonsuk-
dc.contributor.nonIdAuthorChoi, Yong-
dc.contributor.nonIdAuthorHong, Key Jo-
dc.contributor.nonIdAuthorHu, Wei-
dc.contributor.nonIdAuthorKang, Jihoon-
dc.contributor.nonIdAuthorJung, Jin Ho-
dc.contributor.nonIdAuthorSong, Myung Sung-
dc.contributor.nonIdAuthorKim, Byung-Tae-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorField programmable gate arrays (FPGA)-
dc.subject.keywordAuthorfiltering-
dc.subject.keywordAuthormagnetic resonance imaging (MRI)-
dc.subject.keywordAuthorpositron emission tomography (PET)-
dc.subject.keywordAuthorradiofrequency interference-
dc.subject.keywordPlusPET/MRI SYSTEM-
dc.subject.keywordPlusCOMPATIBLE PET-
dc.subject.keywordPlusACQUISITION-
dc.subject.keywordPlusARTIFACTS-
dc.subject.keywordPlusDETECTOR-
dc.subject.keywordPlusSCANNER-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0