Surface-bonded lead zirconate titanate (PZT) transducers have been widely used for guided wave generation and measurement. For selective actuation and sensing of Lamb wave modes, the sizes of the transducers and the driving frequency of the input waveform should be tuned. For this purpose, a theoretical Lamb wave tuning curve (LWTC) of a specific transducer size is generally obtained. Here, the LWTC plots each Lamb wave mode' amplitude as a function of the driving frequency. However, a discrepancy between experimental and existing theoretical LWTCs has been observed due to little consideration of the bonding layer and the energy distribution between Lamb wave modes. In this study, calibration techniques for theoretical LWTCs are proposed. First, a theoretical LWTC is developed when circular PZT transducers are used for both Lamb wave excitation and sensing. Then, the LWTC is calibrated by estimating the effective PZT size with PZT admittance measurement. Finally, the energy distributions among symmetric and antisymmetric modes are taken into account for better prediction of the relative amplitudes between Lamb wave modes. The effectiveness of the proposed calibration techniques is examined through numerical simulations and experimental estimation of the LWTC using the circular PZT transducers instrumented on an aluminum plate.