Reference-free delamination detection using Lamb waves

Cited 33 time in webofscience Cited 33 time in scopus
  • Hit : 600
  • Download : 195
DC FieldValueLanguage
dc.contributor.authorYeum, Chul Minko
dc.contributor.authorSohn, Hoonko
dc.contributor.authorLim, Hyung Jinko
dc.contributor.authorIhn, Jeong Beomko
dc.date.accessioned2014-08-27-
dc.date.available2014-08-27-
dc.date.created2013-10-30-
dc.date.created2013-10-30-
dc.date.created2013-10-30-
dc.date.issued2014-05-
dc.identifier.citationSTRUCTURAL CONTROL & HEALTH MONITORING, v.21, pp.675 - 684-
dc.identifier.issn1545-2255-
dc.identifier.urihttp://hdl.handle.net/10203/187253-
dc.description.abstractThis paper presents a new Lamb wave-based delamination detection technology that allows detection of delamination in a single wave propagation path without using prior baseline data or a predetermined decision boundary. This study shows that, if delamination exists along a wave propagation path, the first arrival antisymmetric (A(0)) mode is followed by other A(0) modes reflected from the inside of the delamination. Unlike other conventional Lamb wave techniques, the proposed technique takes advantage of the first A(0) mode reflected from the inside delamination to instantly identify the existence of delamination. First, the proposed study employs a dual piezoelectric transducer (PZT), which is composed of a concentric ring and disk PZT segments, for Lamb wave excitation and a circular PZT for sensing. By activating either the circular or ring PZT segment separately, two pitch-catch Lamb wave signals are obtained from the single wave propagation path. Then, a normalized A(0) mode signal is decomposed from the measured Lamb wave signals using a previously developed mode decomposition technique, and the first A(0) mode reflected from the delamination is further extracted by using a matching pursuit algorithm. Finally, a reference-free damage classifier is built on the extracted A(0) mode reflection from the delamination. Because the proposed technique does not require baseline signals during the entire delamination detection process, robust delamination detection has been achieved even under varying temperature conditions. Copyright (c) 2013 John Wiley & Sons, Ltd.-
dc.languageEnglish-
dc.publisherWILEY-BLACKWELL-
dc.titleReference-free delamination detection using Lamb waves-
dc.typeArticle-
dc.identifier.wosid000333698300002-
dc.identifier.scopusid2-s2.0-84897571425-
dc.type.rimsART-
dc.citation.volume21-
dc.citation.beginningpage675-
dc.citation.endingpage684-
dc.citation.publicationnameSTRUCTURAL CONTROL & HEALTH MONITORING-
dc.identifier.doi10.1002/stc.1594-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorSohn, Hoon-
dc.contributor.nonIdAuthorYeum, Chul Min-
dc.contributor.nonIdAuthorIhn, Jeong Beom-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorstructural health monitoring-
dc.subject.keywordAuthorpiezoelectric transducer-
dc.subject.keywordAuthorcomposite structure-
dc.subject.keywordAuthordelamination detection-
dc.subject.keywordAuthormode decomposition-
dc.subject.keywordAuthornondestructive testing-
dc.subject.keywordPlusDAMAGE DETECTION-
dc.subject.keywordPlusIDENTIFICATION-
dc.subject.keywordPlusTEMPERATURE-
dc.subject.keywordPlusPULSE-
dc.subject.keywordPlusBEAMS-
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 33 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0