Development and application of ultrahigh-speed 2G-OCT system for 3d micro-vascular imaging혈관 이미징을 위한 고속 도플러 2 세대 OCT 시스템 개발 및 응용

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 576
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorOh, Wang-Yuhl-
dc.contributor.advisor오왕열-
dc.contributor.authorKim, Sun-Hee-
dc.contributor.author김순희-
dc.date.accessioned2013-09-12T02:35:11Z-
dc.date.available2013-09-12T02:35:11Z-
dc.date.issued2013-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=513471&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/181665-
dc.description학위논문(박사) - 한국과학기술원 : 기계공학전공, 2013.2, [ xi, 78 p. ]-
dc.description.abstractDoppler optical coherence tomography (D-OCT) enables high resolution imaging of spatially-localized motion in the sample, especially in-vivo microvasculature imaging, utilizing the phase-resolved technique that is based on the detection of the phase shift between two temporally separated A-lines. To ensure correlation between the two phase measurements, conventional D-OCT over-samples in the transverse direction reducing the phase de-correlation due to the transverse displacement of the imaging beam at the expense of the imaging speed, i.e., frame rate. Recently several approaches such as optimization of beam scanning pattern in OFDI (optical frequency domain imaging) and dual beam scan using polarization multiplexing in SD-OCT (spectral-domain OCT) were demonstrated to address this issue. We present high-speed Doppler OFDI using frequency multiplexed dual beam illumination. The novel scheme provides a pair of spatially separated beams with an acousto-optic frequency shifter that illuminate the exactly same location on the sample with an adjustable time interval upon the imaging beam scan by the galvanometer. Since each beam is encoded with a distinct frequency shift, the two temporally separated beams are easily de-multiplexed in data processing. We demonstrate high-speed vasculature imaging of a mouse thigh, ankle and brain with 117 Fps imaging speed which could measure 3D image of micro-vascular structure in few seconds. This device could be applied on various research fields on medical treatment and diagnosis and biological research.eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectDoppler-
dc.subjectOCT-
dc.subjectVascular imaging-
dc.subjectOFDI-
dc.subject도플러-
dc.subject광간섭이미징-
dc.subject혈관이미징-
dc.subject주파수대역이미징-
dc.subject혈류측정-
dc.subjectBlood flow-
dc.titleDevelopment and application of ultrahigh-speed 2G-OCT system for 3d micro-vascular imaging-
dc.title.alternative혈관 이미징을 위한 고속 도플러 2 세대 OCT 시스템 개발 및 응용-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN513471/325007 -
dc.description.department한국과학기술원 : 기계공학전공, -
dc.identifier.uid020095027-
dc.contributor.localauthorOh, Wang-Yuhl-
dc.contributor.localauthor오왕열-
Appears in Collection
ME-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0