Comparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge

Cited 70 time in webofscience Cited 59 time in scopus
  • Hit : 1131
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorCho, Soojinko
dc.contributor.authorYim, Jinsukko
dc.contributor.authorShin, Sung Wooko
dc.contributor.authorJung, Hyung-Joko
dc.contributor.authorYun, Chung Bangko
dc.contributor.authorWang, Ming L.ko
dc.date.accessioned2013-08-22T02:22:00Z-
dc.date.available2013-08-22T02:22:00Z-
dc.date.created2012-10-12-
dc.date.created2012-10-12-
dc.date.issued2013-08-
dc.identifier.citationJOURNAL OF BRIDGE ENGINEERING, v.18, no.8, pp.748 - 757-
dc.identifier.issn1084-0702-
dc.identifier.urihttp://hdl.handle.net/10203/175494-
dc.description.abstractCable tension is one of the important indexes of cable integrity as well as bridge stability and can be measured by various tension measurement methods. In this study, three widely used methods (i.e., the lift-off test, electromagnetic sensor method, and vibration method) have been implemented for two multistrand cables of a cable-stayed bridge under construction. The test bridge is Hwamyung Bridge in Korea, which has a prestressed concrete box girder. The field tests are executed during the second tensioning stage just after the installation of the key segment. The tensions are estimated before and after tensioning the cable and 5 days later (i.e., after finishing the tensioning of all the cables). The tensions measured by the three methods are compared with the design tension of the tensioning stage, and all three methods show very good performance in accuracy with minimal difference. Their cost and difficulty are compared based on test experiences. Additionally, an improved vibration method is proposed by ignoring apparent negative bending stiffness identified from measurement errors and validated in this test by improving the accuracy. (C) 2013 American Society of Civil Engineers.-
dc.languageEnglish-
dc.publisherASCE-AMER SOC CIVIL ENGINEERS-
dc.subjectSENSORS-
dc.subjectSYSTEM-
dc.subjectFORCE-
dc.titleComparative Field Study of Cable Tension Measurement for a Cable-Stayed Bridge-
dc.typeArticle-
dc.identifier.wosid000321552100006-
dc.identifier.scopusid2-s2.0-84880564174-
dc.type.rimsART-
dc.citation.volume18-
dc.citation.issue8-
dc.citation.beginningpage748-
dc.citation.endingpage757-
dc.citation.publicationnameJOURNAL OF BRIDGE ENGINEERING-
dc.identifier.doi10.1061/(ASCE)BE.1943-5592.0000421-
dc.contributor.localauthorJung, Hyung-Jo-
dc.contributor.localauthorYun, Chung Bang-
dc.contributor.nonIdAuthorCho, Soojin-
dc.contributor.nonIdAuthorYim, Jinsuk-
dc.contributor.nonIdAuthorShin, Sung Woo-
dc.contributor.nonIdAuthorWang, Ming L.-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorCable-stayed bridges-
dc.subject.keywordAuthorVibration-
dc.subject.keywordAuthorCables-
dc.subject.keywordAuthorTension-
dc.subject.keywordAuthorComparative studies-
dc.subject.keywordAuthorMeasurement-
dc.subject.keywordAuthorCable-
dc.subject.keywordAuthorTension-
dc.subject.keywordAuthorCable-stayed bridge-
dc.subject.keywordAuthorLift-off test-
dc.subject.keywordAuthorEM sensor-
dc.subject.keywordAuthorVibration method-
dc.subject.keywordPlusSENSORS-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusFORCE-
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 70 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0