Close Proximity Effects of Metallic Environments on the Antiparallel Resonant Coil for Near-Field Powering

Cited 12 time in webofscience Cited 13 time in scopus
  • Hit : 391
  • Download : 0
This study verifies close proximity effects of metallic environments on the antiparallel resonant coil for near-field powering based on the theoretical analysis and experimental measurements. Compared to the conventional coil with a forward loop, frequency shifting of the antiparallel resonant coil which consists of forward and reverse loops with opposite-direction currents is unchanged regardless of the proximity of metallic plates. Furthermore, highly efficient near-field powering for metallic objects can be achieved with the antiparallel resonant coil because of the added magnetic field caused by the image current of the metallic plates. © 2013 IEEE.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
2013-06
Language
English
Article Type
Article
Keywords

ANTENNA; DEVICE

Citation

IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, v.61, no.6, pp.3400 - 3403

ISSN
0018-926X
DOI
10.1109/TAP.2013.2247553