CoReHA 2.0: A Software Package for In Vivo MREIT Experiments

Cited 4 time in webofscience Cited 0 time in scopus
  • Hit : 824
  • Download : 891
DC FieldValueLanguage
dc.contributor.authorJeon, Kiwanko
dc.contributor.authorLee, Chang-Ockko
dc.date.accessioned2013-04-11T07:50:34Z-
dc.date.available2013-04-11T07:50:34Z-
dc.date.created2013-04-09-
dc.date.created2013-04-09-
dc.date.created2013-04-09-
dc.date.issued2013-
dc.identifier.citationCOMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE-
dc.identifier.issn1748-670X-
dc.identifier.urihttp://hdl.handle.net/10203/173469-
dc.description.abstractMagnetic resonance electrical impedance tomography (MREIT) is a new medical imaging modality visualizing static conductivity images of electrically conducting subjects. Recently, MREIT has rapidly progressed in its theory, algorithm, and experiment technique and now reached to the stage of in vivo animal experiments. In this paper, we present a software, named CoReHA 2.0 standing for the second version of conductivity reconstructor using harmonic algorithms, to facilitate in vivo MREIT reconstruction of conductivity image. This software offers various computational tools including preprocessing of MREIT data, identification of 2D geometry of the imaging domain and electrode positions, and reconstruction of cross-sectional scaled conductivity images from MREIT data. In particular, in the new version, we added several tools including ramp-preserving denoising, harmonic inpainting, and local harmonic B-2 algorithm to deal with data from in vivo experiments. The presented software will be useful to researchers in the field of MREIT for simulation, validation, and further technical development.-
dc.languageEnglish-
dc.publisherHINDAWI PUBLISHING CORPORATION-
dc.titleCoReHA 2.0: A Software Package for In Vivo MREIT Experiments-
dc.typeArticle-
dc.identifier.wosid000315871400001-
dc.identifier.scopusid2-s2.0-84875660773-
dc.type.rimsART-
dc.citation.publicationnameCOMPUTATIONAL AND MATHEMATICAL METHODS IN MEDICINE-
dc.identifier.doi10.1155/2013/941745-
dc.contributor.localauthorLee, Chang-Ock-
dc.contributor.nonIdAuthorJeon, Kiwan-
dc.description.isOpenAccessY-
dc.type.journalArticleArticle-
dc.subject.keywordPlusELECTRICAL-IMPEDANCE TOMOGRAPHY-
dc.subject.keywordPlusB-Z ALGORITHM-
dc.subject.keywordPlusCONDUCTIVITY IMAGE-RECONSTRUCTION-
dc.subject.keywordPlusDECOMPOSITION-
dc.subject.keywordPlusCONVERGENCE-
dc.subject.keywordPlusSIMULATION-
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 4 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike