When we carry out acoustic holography, step-by-step measurement provides us larger aperture size with same number of microphones. But when we carry out step-by-step measurement, it is blown that sound signal must be stationary. However, when transfer function between input and output signal is time-invariant, we can apply step-by-step measurement to acoustic holography even if sound signal is transient We have to do only some Processing on signals from step-by-step measurements to make the signal data of each step compatiable with other steps. This paper accounts for that processing method.