복합사이클 발전플랜트 폐열회수 보일러의 구성요소 크기비의 최적화Ratio Optimization Between Sizes of Components of Heat Recovery Steam Generator in Combined Cycle Gas Turbine Power Plants

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 941
  • Download : 84
DC FieldValueLanguage
dc.contributor.author인종수ko
dc.contributor.author이상용ko
dc.date.accessioned2009-12-17T08:26:53Z-
dc.date.available2009-12-17T08:26:53Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2009-06-
dc.identifier.citation대한기계학회논문집 B, v.33, no.6, pp.403 - 410-
dc.identifier.issn1226-4881-
dc.identifier.urihttp://hdl.handle.net/10203/15187-
dc.description.abstractThis paper proposes a new approach to find the optimum ratios between sizes of the heat exchangers of the heat recovery steam generator (HRSG) system with limited size to maximize the efficiency of the steam turbine (bottom) cycle of combined cycle power plants (CCPP), but without performing the bottom cycle analysis. This could be achieved by minimizing the unavailable exergy (the sum of the destroyed and the lost exergies) resulted from the heat transfer process of the HRSG system. The present approach is relatively simple and straightforward because the process of the trial-and-error method, typical in performing the bottom cycle analysis for the system optimization, could be avoided. To demonstrate the usefulness of the present method, a single-stage HRSG system was chosen and the optimum evaporation temperature was obtained corresponding to the condition of the maximum useful work. The results show that the optimum evaporation temperature based on the present exergy analysis appears similar to that based on the bottom cycle analysis. Also shown is the dependency of size (NTU) ratios between the heat exchangers on the inlet gas temperature, which is another important factor in determining the optimum condition once overall size of the heat recovery steam generator is given. The present approach turned out to be a useful tool for optimization of the single-stage HRSG systems and can easily be extended to multi-stage systems.-
dc.languageKorean-
dc.language.isokoen
dc.publisher대한기계학회-
dc.title복합사이클 발전플랜트 폐열회수 보일러의 구성요소 크기비의 최적화-
dc.title.alternativeRatio Optimization Between Sizes of Components of Heat Recovery Steam Generator in Combined Cycle Gas Turbine Power Plants-
dc.typeArticle-
dc.subject.alternativeDestroyed Exergyen
dc.subject.alternativeHRSGen
dc.subject.alternativeLost Exergyen
dc.subject.alternativeNTUen
dc.subject.alternativeOptimum Evaporation Temperatureen
dc.type.rimsART-
dc.citation.volume33-
dc.citation.issue6-
dc.citation.beginningpage403-
dc.citation.endingpage410-
dc.citation.publicationname대한기계학회논문집 B-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.identifier.kciidART001345750-
dc.contributor.localauthor이상용-
dc.contributor.nonIdAuthor인종수-
dc.subject.keywordAuthorDestroyed Exergy(파괴 엑서지)-
dc.subject.keywordAuthorHRSG(폐열회수 보일러)-
dc.subject.keywordAuthorLost Exergy(유실엑서지)-
dc.subject.keywordAuthorNTU(전달단위수)-
dc.subject.keywordAuthorOptimum Evaporation Temperature(최적증발온도)-