열선 풍속계 에 의한 진동하는 익형 의 후류 측정Hot-wire measurements of the Near Wake of an Oscillating Airfoil

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 703
  • Download : 4
Results of invesbgabon of the wake downstream of a sinusoidally pitching airfoil using single hot~wire probe me reported. The experimental data are reduced by ensemble average technique for 150 consecutive measurement with 48 sampling points distributed evenly during the period of oscillation. The measurements are caried out for wake velocity And turbulence intensity profiles at several downstream locations for the case of reduced frequencies, K=ωC/2U∞=0.09, 0.13 And 0.2. The corresponding Reynold number, Re=U∞C/ν are 47,000, 40,000 and 27,000.It is observed that with increase of K-value, the wake flow thickness also increases And a second dominant peak is present in turbulence intensity at certain instantaneous angle of attack. Also, the clearly visible vortices region with distinct large male is identified by flow visualization using smoke-wire technique.
Publisher
한국항공우주학회
Issue Date
1983-12
Language
Korean
Citation

한국항공우주학회지, v.11, no.2, pp.18 - 25

ISSN
1225-1348
URI
http://hdl.handle.net/10203/14573
Appears in Collection
AE-Journal Papers(저널논문)