Magnetophoretic immunoassay of allergen-specific IgE in an enhanced magnetic field gradient

Cited 73 time in webofscience Cited 75 time in scopus
  • Hit : 383
  • Download : 193
We demonstrate a novel magnetophoretic immunoassay of allergen-specific immunoglobulin E (IgE) based on the magnetophoretic deflection velocity of a microbead that is proportional to the associated magnetic nanoparticles under enhanced magnetic field gradient in a microchannel. In this detection scheme, two types of house dust mites, Dermatophagoides farinae (D. farinae) and Dermatophagoides pteronyssinus (D. pteronyssinus), were used as the model allergens. Polystyrene microbeads were conjugated with each of the mite extracts followed by incubation with serum samples. The resulting mixture was then reacted with magnetic nanoparticle-conjugated anti-human IgE for detection of allergen-specific IgE by using sandwich immuno-reactions. A ferromagnetic microstructure combined with a permanent magnet was employed to increase the magnetic field gradient (similar to 10(4) T/m) in a microfluidic device. The magnetophoretic velocities of microbeads were measured in a microchannel under applied magnetic field, and the averaged velocity was well correlated with the concentration of allergen-specific IgE in serum. From the analysis of pooled sera obtained from 44 patients, the detection limits of the allergen-specific human IgEs for D. farinae and D. pteronyssinus were determined to be 565 (0.045 IU/mL) and 268 fM (0.021 IU/mL), respectively. These values are 1 order of magnitude lower than those by a conventional CAP system. For evaluation of reproducibility and accuracy, unknown sera were subjected to a blind test by using the developed assay system, and they were compared with the CAP system. As a result, coefficient of variance was less than 10%, and the developed method enabled a fast assay with a tiny amount of serum (similar to 10 mu L).
Publisher
AMER CHEMICAL SOC
Issue Date
2007-03
Language
English
Article Type
Article
Keywords

ANTIBODY-ASSAYS; NANOPARTICLES; DIAGNOSIS; DEVICE; MAGNETOMETER; MANIPULATION; SEPARATION; BIOSENSORS; ACCURACY; SYSTEMS

Citation

ANALYTICAL CHEMISTRY, v.79, pp.2214 - 2220

ISSN
0003-2700
DOI
10.1021/ac061522l
URI
http://hdl.handle.net/10203/14253
Appears in Collection
BS-Journal Papers(저널논문)BiS-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 73 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0