궤환 제어를 이용한 모델 개선법 : 측정 센서 위치와 궤환 이득값 설정Model updating using the feedback exciter : the decision of sensor location & feedback gain

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 425
  • Download : 0
The updating of FE model to match it with the experimental results needs the modal information. There are two cases where this methodology is ill-equip to deal with; under-determined and ill-conditioning problem. The feedback exciter that uses the summation of the white noise and the signals from the measurement sensors multiplied with feedback gains can deal with these problems as the new modal data from the closed loop system generate more constraints the updating parameters should obey. The new modal data from the closed loop system should be different to enhance the condition of the modal sensitivity matrix. In this research, a guide for the selection of the sensor locations and the decision of the corresponding output feedback gains is proposed. This method is based on the sensitivity of the modal data with respect to the feedback gains. Through the proper selection of the exciter and sensor locations and the feedback gain, the eigenvalue sensitivity of the updating parameters which cause the ill-conditioning of the modal sensitivity matrix can be modified and consequently the error contamination in updating parameters are reduced.
Publisher
한국소음진동공학회
Issue Date
2002-05
Language
KOR
Citation

한국소음진동공학회 2002년 춘계학술대회, v.2, pp.802 - 807

URI
http://hdl.handle.net/10203/137798
Appears in Collection
ME-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0