dc.description.abstractRole of the expansion tank in a semi-closed two-phase natural circulation loop was examined analytically with the emphasis placed on the flow instability. Loopwise steady circulation rate was obtained, and conditions for how instability were examined by using the method of the linear stability analysis with perturbations. The homogeneous two-phase model was adopted for the analysis. As well as the pressure at the expansion tank, the length and the cross-sectional area of the tube connected to the expansion tank appeared to be the important parameters determining the flow instability. The system was predicted to be stable with the longer length and the smaller cross-sectional area of the expansion-tank line and also with the higher expansion-tank pressure. (C) 1999 Elsevier Science S.A. All rights reserved.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherElsevier Science Sa-
dc.subject2-PHASE-
dc.titleAn analytical investigation of role of expansion tank in semi-closed two-phase natural circulation loop-
dc.typeArticle-
dc.identifier.wosid000081516300009-
dc.identifier.scopusid2-s2.0-0032669034-
dc.type.rimsART-
dc.citation.volume190-
dc.citation.issue3-
dc.citation.beginningpage353-
dc.citation.endingpage360-
dc.citation.publicationnameNUCLEAR ENGINEERING AND DESIGN-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorLee, Sang Yong-
dc.contributor.nonIdAuthorKim, Young Lyoul-
dc.type.journalArticleArticle-
dc.subject.keywordAuthortwo-phase natural circulation-
dc.subject.keywordAuthorsemi-closed loop-
dc.subject.keywordAuthorexpansion tank-
dc.subject.keywordAuthorflow instabilities-
dc.subject.keywordPlus2-PHASE-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 9 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0