Measurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate

Cited 2 time in webofscience Cited 0 time in scopus
  • Hit : 743
  • Download : 0
In this paper, a new measurement method for the total hemispherical emissivity of surfaces is introduced. A vacuum guarded hot plate apparatus is developed and it is employed for the emissivity measurement. Al, Ag, Au, and Ni coatings and STS 304 plate are used as the specimen. Measured total hemispherical emissivities are 0.05-0.24 with 8.1% uncertainty at most. This proves the reliability of current method even for highly reflective surfaces. [DOI: 10.1115/1.4005748]
Publisher
ASME-AMER SOC MECHANICAL ENG
Issue Date
2012-11
Language
English
Article Type
Article
Keywords

CALORIMETRIC TECHNIQUE; TEMPERATURE; HEAT

Citation

JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, v.134, no.11

ISSN
0022-1481
DOI
10.1115/1.4005748
URI
http://hdl.handle.net/10203/103115
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 2 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike