Effective suppression of pneumatic vibration isolators by using input-output linearization and time delay control

Cited 35 time in webofscience Cited 0 time in scopus
  • Hit : 1078
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorChang, Pyung-hunko
dc.contributor.authorHan, Dong Kiko
dc.contributor.authorShin, Yun-hoko
dc.contributor.authorKim, Kwang-joonko
dc.date.accessioned2013-03-11T21:57:39Z-
dc.date.available2013-03-11T21:57:39Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2010-05-
dc.identifier.citationJOURNAL OF SOUND AND VIBRATION, v.329, no.10, pp.1636 - 1652-
dc.identifier.issn0022-460X-
dc.identifier.urihttp://hdl.handle.net/10203/100426-
dc.description.abstractThis paper presents a new state space representation of pneumatic vibration isolators (PVIs) and a design of a robust control, Time Delay Control (TDC), based on it. The new state space model, derived by using the input-output linearization method, is of the phase variable form with the air mass-flow as the control input. This model offers a framework that enables simultaneous suppression of both seismic vibration and direct disturbance (or payload disturbance) with an accelerometer only. Based on this model, TDC is designed and verified with experiments on a single chamber PVI with an accelerometer only. In the experiment, the PVI with TDC successfully suppresses seismic vibration and direct disturbance, both individually and simultaneously. Faced with seismic vibration, the transmissibility of the PVI with TDC has virtually no resonance peak at low frequency; under direct disturbance, the former achieves a 68 percent reduction in settling time of the latter. The final analysis of experimental result shows that TDC effectively estimates the modeling error along with other uncertainties and cancels them, while achieving desired closed-loop dynamics. (C) 2009 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.publisherACADEMIC PRESS LTD- ELSEVIER SCIENCE LTD-
dc.subjectPRESSURE DIFFERENTIATOR-
dc.subjectISOLATION TABLE-
dc.subjectACTIVE CONTROL-
dc.subjectSYSTEMS-
dc.subjectACCELEROMETER-
dc.subjectCHAMBER-
dc.subjectNOISE-
dc.subjectMODEL-
dc.titleEffective suppression of pneumatic vibration isolators by using input-output linearization and time delay control-
dc.typeArticle-
dc.identifier.wosid000274926800003-
dc.identifier.scopusid2-s2.0-77954384281-
dc.type.rimsART-
dc.citation.volume329-
dc.citation.issue10-
dc.citation.beginningpage1636-
dc.citation.endingpage1652-
dc.citation.publicationnameJOURNAL OF SOUND AND VIBRATION-
dc.identifier.doi10.1016/j.jsv.2009.12.003-
dc.contributor.localauthorKim, Kwang-joon-
dc.contributor.nonIdAuthorChang, Pyung-hun-
dc.contributor.nonIdAuthorHan, Dong Ki-
dc.type.journalArticleArticle-
dc.subject.keywordPlusPRESSURE DIFFERENTIATOR-
dc.subject.keywordPlusISOLATION TABLE-
dc.subject.keywordPlusACTIVE CONTROL-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordPlusACCELEROMETER-
dc.subject.keywordPlusCHAMBER-
dc.subject.keywordPlusNOISE-
dc.subject.keywordPlusMODEL-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 35 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0