Sub-optimal design procedure of valve-mode magnetorheological fluid dampers for structural control

Cited 7 time in webofscience Cited 0 time in scopus
  • Hit : 331
  • Download : 0
The systematic sub-optimal design procedure for valve-mode magnetorheological fluid (MR) dampers is proposed. The design procedure for MR dampers has been developed from considerations on optimization problems and magnetic analysis. According to the proposed design procedure, a four-stage valve-mode MR damper with the capacity of about 10 kN has been designed, manufactured and tested. The effectiveness of the proposed sub-optimal design procedure has been confirmed through a series of tests of the 10 kN MR damper using a servo-hydraulic universal testing machine.
Publisher
SPRINGER
Issue Date
2011-05
Language
English
Article Type
Article
Citation

KSCE JOURNAL OF CIVIL ENGINEERING, v.15, no.5, pp.867 - 873

ISSN
1226-7988
URI
http://hdl.handle.net/10203/95913
Appears in Collection
CE-Journal Papers(저널논문)