DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Hyunduk | ko |
dc.contributor.author | Cho, Gyuseong | ko |
dc.contributor.author | Kang, Bo-Sun | ko |
dc.date.accessioned | 2013-03-09T03:57:06Z | - |
dc.date.available | 2013-03-09T03:57:06Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 2009-10 | - |
dc.identifier.citation | NUCLEAR INSTRUMENTS METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.610, no.1, pp.302 - 306 | - |
dc.identifier.issn | 0168-9002 | - |
dc.identifier.uri | http://hdl.handle.net/10203/95299 | - |
dc.description.abstract | So far the origin of the mechanism of light emission in the sonoluminescence has not elucidated whether it is due to blackbody radiation or bremsstrahlung. The final goal of our study is measuring X-ray energy spectrum using high-sensitivity cadmium telluride (CdTe) detector in order to obtain information for understanding sonoluminescence phenomena. However, the scope of this report is the measurement of X-ray spectrum using a high-resolution CdTe detector and determination of CdTe detector response function to obtain the corrected spectrum from measured soft X-ray source spectrum. In general, the measured spectrum was distorted by the characteristics of CdTe detector. Monte Carlo simulation code, MCNP, was used to obtain the reference response function of the CdTe detector. The X-ray spectra of (57)Co, (133)Ba, and (241)Am were obtained by a 4 x 4 x 1.0(t) mm(3) CdTe detector at room temperature. (C) 2009 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | RAY | - |
dc.subject | SEMICONDUCTOR | - |
dc.subject | SPECTRA | - |
dc.title | Study on response function of CdTe detector | - |
dc.type | Article | - |
dc.identifier.wosid | 000272873800075 | - |
dc.identifier.scopusid | 2-s2.0-71749098744 | - |
dc.type.rims | ART | - |
dc.citation.volume | 610 | - |
dc.citation.issue | 1 | - |
dc.citation.beginningpage | 302 | - |
dc.citation.endingpage | 306 | - |
dc.citation.publicationname | NUCLEAR INSTRUMENTS METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | - |
dc.identifier.doi | 10.1016/j.nima.2009.05.097 | - |
dc.contributor.localauthor | Cho, Gyuseong | - |
dc.contributor.nonIdAuthor | Kim, Hyunduk | - |
dc.contributor.nonIdAuthor | Kang, Bo-Sun | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordAuthor | CdTe | - |
dc.subject.keywordAuthor | X-ray detector | - |
dc.subject.keywordAuthor | Response | - |
dc.subject.keywordAuthor | Asymmetry | - |
dc.subject.keywordPlus | RAY | - |
dc.subject.keywordPlus | SEMICONDUCTOR | - |
dc.subject.keywordPlus | SPECTRA | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.