소형 압축기를 이용한 관성관형 맥동관 냉동기의 성능 특성에 대한 실험적 연구An Experimental Study on Performance of the Inertance Pulse Tube Refrigerator using a Small Compressor

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 357
  • Download : 0
This paper describes an experimental study on the inertance pulse tube refrigerator using a small compressor. The purpose of this experimental study is to identify the performance of the inertance pulse tube refrigerator for various operating conditions and to obtain the optimum configuration. The dead volume effect is verified by two experimental apparatuses with different dead volumes between the compressor and the aftercooler. The refrigerator of the smaller dead volume shows better performance. The influence of operating frequency and charging pressure on the performance of the refrigerator is experimentally investigated. Reducing the regenerator mesh size improves the performance of the refrigerator. Finally, the inertance pulse tube refrigerator has maximum cooling capacity at the specific combination of the pulse tube length and the inertance tube length. The loss analysis is used to analyze and predict the optimum condition of the pulse tube refrigerator.
Publisher
대한설비공학회
Issue Date
2005-06
Language
Korean
Citation

설비공학 논문집, v.17, no.6, pp.552 - 559

ISSN
1229-6422
URI
http://hdl.handle.net/10203/92004
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.