DC Field | Value | Language |
---|---|---|
dc.contributor.author | Baek, WP | ko |
dc.contributor.author | Kim, HC | ko |
dc.contributor.author | Chang, Soon-Heung | ko |
dc.date.accessioned | 2013-03-03T04:47:55Z | - |
dc.date.available | 2013-03-03T04:47:55Z | - |
dc.date.created | 2012-02-06 | - |
dc.date.created | 2012-02-06 | - |
dc.date.issued | 1997-12 | - |
dc.identifier.citation | NUCLEAR ENGINEERING AND DESIGN, v.178, no.3, pp.331 - 337 | - |
dc.identifier.issn | 0029-5493 | - |
dc.identifier.uri | http://hdl.handle.net/10203/77291 | - |
dc.description.abstract | The prediction capability of the 1995 CHF look-up table (Groeneveld D.C., et al., Nucl. Eng. Des. 163 (1996) 1-23) is independently assessed based on the KAIST data base consisting of 10 822 data for uniformly-heated, vertical, round tubes. This confirms the error statistics for the heat balance method reported by Groeneveld et al. and shows overall average and RMS errors of 4.2 and 36.7%, respectively, for the direct substitution method. The new 1995 table shows better prediction capability than the 1986 AECL-UO table (Groeneveld et al., 1986), especially for the low-pressure, low-flow region. The error analysis indicates the length effect even for significantly long tubes. (C) 1997 Elsevier Science S.A. | - |
dc.language | English | - |
dc.publisher | ELSEVIER SCIENCE SA | - |
dc.subject | CRITICAL HEAT-FLUX | - |
dc.subject | INTERNAL TWISTED TAPES | - |
dc.subject | MARGIN PREDICTION | - |
dc.subject | TUBES | - |
dc.title | An independent assessment of Groeneveld et al.s 1995 CHF look-up table | - |
dc.type | Article | - |
dc.identifier.wosid | 000071853400007 | - |
dc.identifier.scopusid | 2-s2.0-0031553250 | - |
dc.type.rims | ART | - |
dc.citation.volume | 178 | - |
dc.citation.issue | 3 | - |
dc.citation.beginningpage | 331 | - |
dc.citation.endingpage | 337 | - |
dc.citation.publicationname | NUCLEAR ENGINEERING AND DESIGN | - |
dc.contributor.localauthor | Chang, Soon-Heung | - |
dc.contributor.nonIdAuthor | Baek, WP | - |
dc.contributor.nonIdAuthor | Kim, HC | - |
dc.type.journalArticle | Article | - |
dc.subject.keywordPlus | CRITICAL HEAT-FLUX | - |
dc.subject.keywordPlus | INTERNAL TWISTED TAPES | - |
dc.subject.keywordPlus | MARGIN PREDICTION | - |
dc.subject.keywordPlus | TUBES | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.