Rapid determination of Pu isotopes and atom ratios in small amounts of environmental samples by an on-line sample pre-treatment system and isotope dilution high resolution inductively coupled plasma mass spectrometry

Cited 97 time in webofscience Cited 99 time in scopus
  • Hit : 316
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKim, CSko
dc.contributor.authorKim, CKko
dc.contributor.authorLee, JIko
dc.contributor.authorLee, Kun Jaiko
dc.date.accessioned2013-02-28T00:31:53Z-
dc.date.available2013-02-28T00:31:53Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2000-
dc.identifier.citationJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, v.15, no.3, pp.247 - 255-
dc.identifier.issn0267-9477-
dc.identifier.urihttp://hdl.handle.net/10203/71758-
dc.description.abstractIsotope dilution (ID) high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS) combined with an on-line sample pre-treatment method was applied to the trace determination of Pu-239, Pu-240 and Pu-240/Pu-239 ratios in small amounts of environmental samples. To reduce the interference effect of U-238, a microconcentric nebulizer, MCN-6000(R), was used as a sample introduction method, which showed a 5-fold lower UH+/U+ ratio than the conventional pneumatic nebulizer. U-238 separation and preconcentration of Pu were performed sequentially on two extraction resins, Sr-Spec(R) and TEVA-Spec(R), which were sequentially combined in PrepLab(TM), an integrated liquid handing system. By reducing the final sample volume to 2.4 ml, injecting it into the HR-ICP-MS system and employing the MCN-6000, the analysis of Pu isotopes is feasible in 1 g of soil and sediment having the environmental level of Pu. The detection limits for Pu-239, Pu-240 and Pu-242 by this method were about 4 fg ml(-1) (9.2 mu Bq ml(-1)), 3 fg ml(-1) (25 mu Bq ml(-1)) and 6 fg ml(-1) (0.87 mu Bq ml(-1)), respectively. These represent total amounts of 9.6, 7.2 and 14 fg for Pu-239, Pu-240 and Pu-242 in a final sample volume. After digestion of the sample, the U-238 elimination and Pu preconcentration procedures were fully automated. Sample preparation is therefore far simpler and the full sample analysis process can be achieved within about 5 h. The analytical reliability was confirmed using several certified or standard reference materials (NIST SRM-4350b, IAEA-6, IAEA-300, IAEA-367, IAEA-368, IAEA-375).-
dc.languageEnglish-
dc.publisherROYAL SOC CHEMISTRY-
dc.subjectLONG-LIVED RADIONUCLIDES-
dc.subjectFALLOUT PLUTONIUM-
dc.subjectPALOMARES SPAIN-
dc.subjectINVENTORY-
dc.subjectHYDRIDE-
dc.subjectURANIUM-
dc.subjectPU-238-
dc.subjectSOILS-
dc.titleRapid determination of Pu isotopes and atom ratios in small amounts of environmental samples by an on-line sample pre-treatment system and isotope dilution high resolution inductively coupled plasma mass spectrometry-
dc.typeArticle-
dc.identifier.wosid000085594900002-
dc.type.rimsART-
dc.citation.volume15-
dc.citation.issue3-
dc.citation.beginningpage247-
dc.citation.endingpage255-
dc.citation.publicationnameJOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY-
dc.identifier.doi10.1039/a907739a-
dc.contributor.localauthorLee, Kun Jai-
dc.contributor.nonIdAuthorKim, CS-
dc.contributor.nonIdAuthorKim, CK-
dc.contributor.nonIdAuthorLee, JI-
dc.type.journalArticleArticle-
dc.subject.keywordPlusLONG-LIVED RADIONUCLIDES-
dc.subject.keywordPlusFALLOUT PLUTONIUM-
dc.subject.keywordPlusPALOMARES SPAIN-
dc.subject.keywordPlusINVENTORY-
dc.subject.keywordPlusHYDRIDE-
dc.subject.keywordPlusURANIUM-
dc.subject.keywordPlusPU-238-
dc.subject.keywordPlusSOILS-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 97 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0