인간실수를 고려한 월성 원자력발전소 안전계통의 최적점검주기에 관한 연구Optimal Inspection Periods of Safety System of Wolsung Nuclear Power Plant Unit 1 with Human Error Consideration

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 487
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorMok, Jin Ilko
dc.contributor.authorSeong, Poong Hyunko
dc.date.accessioned2013-02-27T06:09:05Z-
dc.date.available2013-02-27T06:09:05Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued1994-03-
dc.identifier.citationNUCLEAR ENGINEERING AND TECHNOLOGY , v.26, no.1, pp.9 - 18-
dc.identifier.issn0372-7327-
dc.identifier.urihttp://hdl.handle.net/10203/66896-
dc.description.abstractThe engineered safeguards of Wolsung nuclear power plant unit 1 contain redundant systems of 2-out-of-3 logic which are not operating under normal conditions but are called upon to act when emergency conditions develop. To ensure their operability, the systems are periodically tested. In this work, we develop the unavailability formulae for 2-out-of-3 logic configurations which take into account the failure probability of the channels tested due to human error in the simultaneous testing scheme. We also develop the model for the probability that the reactor is tripped during the surveillance test due to either system failure or human error. We determined the optimal inspection periods of safety systems, taking into account both the unavailability of the safety system and the probability that the reactor is tripped during the surveillance test. We compared the results with the inspection periods currently used at Wolsung NPP Unit 1. As a result, the inspection periods obtained using a minimum human error (8.24 x 1-6 ) are shorter than those currently used in Wolsung NPP unit 1 whereas the inspection periods obtained using a maximum human error are (4.44 x 10-4 ) longer than those used in Wolsung NPP unit 1.-
dc.languageKorean-
dc.publisher한국원자력학회-
dc.title인간실수를 고려한 월성 원자력발전소 안전계통의 최적점검주기에 관한 연구-
dc.title.alternativeOptimal Inspection Periods of Safety System of Wolsung Nuclear Power Plant Unit 1 with Human Error Consideration-
dc.typeArticle-
dc.type.rimsART-
dc.citation.volume26-
dc.citation.issue1-
dc.citation.beginningpage9-
dc.citation.endingpage18-
dc.citation.publicationnameNUCLEAR ENGINEERING AND TECHNOLOGY-
dc.contributor.localauthorSeong, Poong Hyun-
dc.contributor.nonIdAuthorMok, Jin Il-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0