DISSOLVED-OXYGEN CONCENTRATION REGULATION USING AUTO TUNING PROPORTIONAL INTEGRAL DERIVATIVE CONTROLLER IN FERMENTATION PROCESS

Cited 18 time in webofscience Cited 0 time in scopus
  • Hit : 606
  • Download : 0
A novel control method involving an automatic tuning of digital proportional-integral-derivative controller parameters has been developed for better regulation of dissolved oxygen concentration by manipulating agitation speed in batch fermentation processes. Heuristic reasoning allows the proportional-integral-derivative controller to reach improved tuning decisions based upon the supervision of certain control performance indices in the same cognitive manner as in expert control.