Characterization and performance enhancement of gas avalanche microdetectors for radiation position detection방사선 위치검출을 위한 기체 증폭형 검출기의 특성분석 및 성능향상에 관한 연구

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 454
  • Download : 0
DC FieldValueLanguage
dc.contributor.advisorCho, Gyu-Seong-
dc.contributor.advisor조규성-
dc.contributor.authorKim, Ho-Kyung-
dc.contributor.author김호경-
dc.date.accessioned2011-12-14T08:04:46Z-
dc.date.available2011-12-14T08:04:46Z-
dc.date.issued2001-
dc.identifier.urihttp://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=165692&flag=dissertation-
dc.identifier.urihttp://hdl.handle.net/10203/48916-
dc.description학위논문(박사) - 한국과학기술원 : 원자력공학과, 2001.2, [ vi, 110 p. ]-
dc.description.abstractGas detectors have definite advantages over other types of detectors: large-sensitive area, flexible geometry, low cost, radiation resistance etc. With these merits as well as low density they are very attractive for tracking devices in high-energy physics experiments and other applications. Nevertheless they suffer from some problems: dead zone effect, electrical breakdown, and angular dependence. In two-dimensional gas avalanche pixel detector, the dead zone effect is most predominant because of the drift field perturbation by the readout bus. It is found that the conductive coating onto the substrate is the best method to minimize this effect when the ratio between the surface coating conductivity and the substrate bulk conductivity is greater than 0.1 in unit of centimeter. Otherwise, avoiding the serious dead zone effect, and simultaneously allowing good spatial resolution and large avalanche signal, the 100 ㎛-pitch detector is optimum. In order to avoid the permanent damage of electrical breakdown due to sparking, the charge preamplification method is most desirable because it can share the avalanche gain to the preamplifying structure and the electrodes of detector so it reduces the operation voltage. However, the conventional gas electron multiplier (GEM) as the preamplifying structure shows an unstable signal output as a function of time, which is due to the charging effect. A new GEM having very steep wall sides and high-aspect ratio has been made by the LIGA process, and which can lead to stable signal output and larger avalanche signal. First experimental results show a large avalanche gain (lower limit to $3×10^3)$, and a good time stability (~ 2% during 30 min). A columnar cesium iodide (CsI) layer was initially intended as a dominant ionization source in gas avalanche microdetectors to overcome the angular dependence of the detector performance upon the incident radiation. However, based upon the results from the electric field simulation and ...eng
dc.languageeng-
dc.publisher한국과학기술원-
dc.subjectLIGA process-
dc.subjectdead zone-
dc.subjectgas avalanche microdetector-
dc.subjectradiation detector-
dc.subjectsecondary electron emission-
dc.subject이차전자 발생-
dc.subject엑스레이 식각 방법-
dc.subject둔감영역-
dc.subject기체 증폭형 검출기-
dc.subject방사선 검출기-
dc.titleCharacterization and performance enhancement of gas avalanche microdetectors for radiation position detection-
dc.title.alternative방사선 위치검출을 위한 기체 증폭형 검출기의 특성분석 및 성능향상에 관한 연구-
dc.typeThesis(Ph.D)-
dc.identifier.CNRN165692/325007-
dc.description.department한국과학기술원 : 원자력공학과, -
dc.identifier.uid000965120-
dc.contributor.localauthorKim, Ho-Kyung-
dc.contributor.localauthor김호경-
Appears in Collection
NE-Theses_Ph.D.(박사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike