Wear of water walls in a commercial circulating fluidized bed combustor with two gas exits

Cited 20 time in webofscience Cited 35 time in scopus
  • Hit : 1162
  • Download : 1687
The tube thickness profiles of water walls, including wing walls, were measured in a large commercial circulating fluidized bed furnace (200 tonnes steam/h, 4.97 m x 9.90 m x 28.98 m high) by means of an ultrasonic thickness gauge in order to investigate tube wastage patterns. Wastage of all water walls, including wing walls, was significant in the transition region just above the refractory lining around the circumference of the combustor, especially at the center of the sidewalls and both sides of the front and rear walls. The lateral wear profile seemed to be influenced mainly by secondary flow, stronger toward the center than in the corners, and somewhat by the wing walls and two gas exits. Wastage of some tubes was also found to be appreciable around the gas exit. The lateral profiles of tube thickness at the gas exit level and other findings indicate asymmetric flows between the two exits. (C) 2007 Elsevier B.V. All rights reserved.
Publisher
ELSEVIER SCIENCE SA
Issue Date
2007-09
Language
English
Article Type
Article
Keywords

EROSION

Citation

POWDER TECHNOLOGY, v.178, no.3, pp.143 - 150

ISSN
0032-5910
DOI
10.1016/j.powtec.2007.04.013
URI
http://hdl.handle.net/10203/3498
Appears in Collection
CBE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 20 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0