SIMPLEX: Multiple phase-cycled bSSFP quantitative magnetization transfer imaging with physic-guided simulation learning of neural network

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 55
  • Download : 0
Most quantitative magnetization transfer (qMT) imaging methods require acquiring additional quantitative maps (such as T1) for data fitting. A method based on multiple phase-cycled bSSFP was recently proposed to enable high-resolution 3D qMT imaging based on least square fitting without any extra acquisition, and thus has high potential for simplifying the qMT procedure. However, the quantification of qMT parameters with this method was suboptimal, limiting its potential for clinical application despite its simpler protocol and higher spatial resolution. To improve the fitting of qMT data obtained with multiple phase-cycled bSSFP, we propose SIMulation-based Physics-guided Learning of neural network for qMT parameters EXtraction, or SIMPLEX. In contrast to previous deep learning supervised approaches for quantitative MR that require the acquisition of input data and corresponding ground truth for training, we leveraged the MR signal model to generate training samples without expensive data curation. The network was trained exclusively with simulation data by predicting the simulation parameters. The same network was applied directly to in-vivo data without additional training. The approach was verified with both simulation and in-vivo data. SIMPLEX showed a decrease in fitting mean squared error for all simulation data compared to the existing least-square fitting method. The in-vivo experiment revealed that the network performed well with the real in vivo data unseen during training. For all experiments, we observed that SIMPLEX consistently improved the quantification quality of the qMT parameters whilst being more robust to noise compared to the prior technique. The proposed SIMPLEX will expedite the routine clinical application of qMT by providing qMT parameters (exchange rate, pool fraction) as well as T1, T2, and ΔB0 maps simultaneously with high spatial resolution, better reliability, and reduced processing time.
Publisher
ACADEMIC PRESS INC ELSEVIER SCIENCE
Issue Date
2023-11
Language
English
Article Type
Article
Citation

NEUROIMAGE, v.284, no.1

ISSN
1053-8119
DOI
10.1016/j.neuroimage.2023.120449
URI
http://hdl.handle.net/10203/315481
Appears in Collection
BiS-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0