Analysis of Effect of Increasing Motor Voltage from 690-V to 1000-V on 1.5-MW Motor Drive Design for Large-Scale Electric Propulsion Ship

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 93
  • Download : 0
For large-scale electric propulsion ship, line voltage of independent microgrid in the ship can be increased from 690-V to 1000-V to reduce filter weight of grid-side systems. This paper investigates the advantages and disadvantages in terms of 1.5-MW motor drive design when the rated motor voltage is increased from 690-V to 1000-V. The analysis is performed in the order of induction motor, DC-link capacitor, and switching device for motor drive. The simulation results from MATLAB/SIMULINK are expressed by map considering various motor operating conditions. For fair comparison, the cost analysis is also conducted. As a result, this study finds that the motor drive loss and switch junction temperature are reduced, but the motor drive efficiency is also decreased at low-speed and low-torque operating condition. Therefore, we conclude that there is the need for research about improvement of motor drive efficiency at this operating condition.
Publisher
Institute of Electrical and Electronics Engineers Inc.
Issue Date
2022-09
Language
English
Citation

20th IEEE International Power Electronics and Motion Control Conference, PEMC 2022, pp.633 - 638

DOI
10.1109/PEMC51159.2022.9962942
URI
http://hdl.handle.net/10203/312658
Appears in Collection
GT-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.