Evaluation of RF shielding materials to improve MR image of hybrid PET/MRIEvaluation of RF shielding materials to improve MR image of hybrid PET/MRI

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 548
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorLim, Hyun Keongko
dc.contributor.authorChoi, Yongko
dc.contributor.authorJung, Jin Hoko
dc.contributor.authorJung, Jiwoongko
dc.contributor.authorOh, Changheunko
dc.contributor.authorPark, Hyun-wookko
dc.contributor.authorKim, Jong Gukko
dc.date.accessioned2022-04-13T06:47:41Z-
dc.date.available2022-04-13T06:47:41Z-
dc.date.created2022-04-04-
dc.date.created2022-04-04-
dc.date.created2022-04-04-
dc.date.created2022-04-04-
dc.date.issued2022-04-
dc.identifier.citationJOURNAL OF THE KOREAN PHYSICAL SOCIETY, v.80, no.7, pp.640 - 646-
dc.identifier.issn0374-4884-
dc.identifier.urihttp://hdl.handle.net/10203/292558-
dc.description.abstractHybrid PET/MRI is a useful imaging system that can improve diagnostic accuracy by providing both functional and anatomical information. However, the combination of PET and MRI can lead to mutual interference, which can degrade the performances of both imaging systems. One of the methods that is capable of preserving the performance of both modalities is to apply RF shielding to PET detectors and electronics. The purpose of this study was to propose a new RF shielding method using Au-plated conductive fabric (PCF) tape that could not only minimize RF interference and eddy current, but that could also be applied to complex PET gantry and detector module structures more easily than thin Cu foils, which have been widely used as a shielding material for hybrid PET/MRI systems. To evaluate the performance of the proposed new RF shielding method, the effects of the two RF shield materials (Cu and Au) on the B1 + field generated by the RF head coil were estimated using a computer simulation method. The effects of the Au PCF tape and Cu foil on the homogeneity and SNR of the MR image were also experimentally evaluated using a commercial 3-T MRI. The uniformity of the B1 + field map was slightly decreased by the use of Cu and Au RF shields. The deterioration in the MR image quality caused by the Au PCF tape was less than that caused by Cu foil. The simulation and experimental results indicate that Au PCF tape can serve as an alternative shielding material that reduces RF interference and eddy current for hybrid PET/MRI systems.-
dc.languageEnglish-
dc.publisherKOREAN PHYSICAL SOC-
dc.titleEvaluation of RF shielding materials to improve MR image of hybrid PET/MRI-
dc.title.alternativeEvaluation of RF shielding materials to improve MR image of hybrid PET/MRI-
dc.typeArticle-
dc.identifier.wosid000767699600001-
dc.identifier.scopusid2-s2.0-85126099392-
dc.type.rimsART-
dc.citation.volume80-
dc.citation.issue7-
dc.citation.beginningpage640-
dc.citation.endingpage646-
dc.citation.publicationnameJOURNAL OF THE KOREAN PHYSICAL SOCIETY-
dc.identifier.doi10.1007/s40042-022-00459-1-
dc.identifier.kciidART002830947-
dc.contributor.localauthorPark, Hyun-wook-
dc.contributor.nonIdAuthorLim, Hyun Keong-
dc.contributor.nonIdAuthorChoi, Yong-
dc.contributor.nonIdAuthorJung, Jin Ho-
dc.contributor.nonIdAuthorJung, Jiwoong-
dc.contributor.nonIdAuthorOh, Changheun-
dc.contributor.nonIdAuthorKim, Jong Guk-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorHybrid PET-
dc.subject.keywordAuthorMRI-
dc.subject.keywordAuthorRF shielding-
dc.subject.keywordAuthorAu PCF tape-
dc.subject.keywordAuthorCu foil-
dc.subject.keywordAuthorComputer simulation-
dc.subject.keywordPlusPET DETECTOR-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusDESIGN-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlusCOIL-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0