(A) high dynamic range neural recording system with automatic adaptive gain control utilizing dynamic zoom delta-sigma ADC적응형 이득 조절이 가능한 동적 확대형 델타-시그마 아날로그-디지털 컨버터 기반 뇌신경신호 기록 시스템

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 346
  • Download : 0
Recently, closed-loop electrical stimulation has been one of the leading neurotherapeutic treatments for various neural disorders. The closed-loop electrical stimulation simultaneously records neural signals and stimulates the focus of the neural disease. The closed-loop stimulation has higher treatment efficiency and fewer side effects compared to open-loop stimulation; however, stimulation artifacts are applied to the neural signal and increase the requirements of the neural signal recording system design. In order to design the bidirectional neural interface, the neural recording system should meet the requirements of high dynamic range, low power consumption and sufficient bandwidth. There are many limitations that complicate satisfying all of these conditions using conventional neural recording topologies. In this paper, automatic adaptive gain control with dynamic zoom $\Delta\Sigma$ ADC is proposed to overcome the limitations of the conventional topologies. The automatic adaptive gain controller adaptively changes the gain of an amplifier according to the input signal of the system and controls the over-sampling ratio of the zoom $\Delta\Sigma$ ADC clock. This optimizes SNDR and saves power consumption. The neural recording system was realized using 0.18 $\mu$m CMOS process. The system consumes minimal power (10.9 $\mu$W) and has peak SNDR performance of 77.3 dB, with an expanded input linear range.
Advisors
Je, Minkyuresearcher제민규researcher
Description
한국과학기술원 :전기및전자공학부,
Publisher
한국과학기술원
Issue Date
2019
Identifier
325007
Language
eng
Description

학위논문(석사) - 한국과학기술원 : 전기및전자공학부, 2019.2,[vi, 67 p. :]

Keywords

Neural recording system▼adynamic range▼adynamic zoom $\Delta\Sigma$ ADC▼alow power bio sensor▼abidirectional neural interface▼aautomatic adaptive gain control▼aclosed-loop electrical stimulation; 뇌신경신호 기록 시스템▼a동적 영역▼a동적 확대형 델타-시그마 아날로그-디지털 컨버터▼a저전력 바이오 센서▼a양방향 뇌신경 인터페이스▼a적응형 자동 이득 조절▼a폐루프 전기 자극

URI
http://hdl.handle.net/10203/266925
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=843792&flag=dissertation
Appears in Collection
EE-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0