NCC-based stitching performance in MFP frameworkMFP를 이용한 NCC 기반의 의료 영상 정합

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 389
  • Download : 0
In clinics, long-length medical images such as lower limb or whole spine are required for diagnostic purposes. Because of limited x-ray detector panel size, long-length images should be acquired by stitching of multiple images with minimum overlap area. To find the stitching point, similarity is measured in overlapped area between two serial images by calculating normalized cross correlation (NCC). Typically, medical image stitching technique introduces a lead ruler as a marker for stitching. However, marker-based stitching can result in discordance of anatomical structures near stitching line when there is a patient movement during sequential image acquisition. Therefore, anatomical-structure-based stitching is the ideal method. Nevertheless, scattering of x-rays and noise from detector panel decrease the similarity of overlapped area from two serial images, which can lead to erroneous stitching. In this study, we suggested the introduction of multi-frequency processing (MFP) framework for anatomical-structure-based-stitching to reduce the stitching error. To reduce the calculation time, fast Fourier transform (FFT) was used. Sample images for NCC calculation were selected on the overlapped region. MFP was applied for these selected samples to get edged enhanced images. Using MFP applied samples, NCC calculation was carried out to determine stitching point. After determinant of stitching point, seam-line is eliminated using triangulation average blending. NCC-based stitching in MFP framework outperformed the simple NCC-based stitching. Stitching in MFP framework significantly reduces the possibility of erroneous stitching. Introduction of MFP before NCC calculation greatly increased the performance of stitching. Anatomical-structure-based stitching without a lead ruler can be successfully achieved without visible error.
Advisors
Cho, Seungryongresearcher조승룡researcher
Description
한국과학기술원 :원자력및양자공학과,
Publisher
한국과학기술원
Issue Date
2019
Identifier
325007
Language
eng
Description

학위논문(석사) - 한국과학기술원 : 원자력및양자공학과, 2019.2,[ii, 15 p. :]

Keywords

Stitching▼aMFP▼aNCC▼aradiographic image▼amedical panoramic image; 영상정합▼aMFP▼aNCC▼a방사선 영상▼a의료영상정합

URI
http://hdl.handle.net/10203/266681
Link
http://library.kaist.ac.kr/search/detail/view.do?bibCtrlNo=843352&flag=dissertation
Appears in Collection
NE-Theses_Master(석사논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0