Nanoscale FET-Based Transduction toward Sensitive Extended-Gate Biosensors

Cited 25 time in webofscience Cited 15 time in scopus
  • Hit : 349
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKwon, Jaeko
dc.contributor.authorLee, Byung-Hyunko
dc.contributor.authorKim, Seong-Yeonko
dc.contributor.authorPark, Jun-Youngko
dc.contributor.authorBae, Hagyoulko
dc.contributor.authorChoi, Yang-Kyuko
dc.contributor.authorAhn, Jae-Hyukko
dc.date.accessioned2019-07-23T07:20:10Z-
dc.date.available2019-07-23T07:20:10Z-
dc.date.created2019-07-23-
dc.date.created2019-07-23-
dc.date.issued2019-06-
dc.identifier.citationACS SENSORS, v.4, no.6, pp.1724 - 1729-
dc.identifier.issn2379-3694-
dc.identifier.urihttp://hdl.handle.net/10203/263751-
dc.description.abstractOwing to their simple and low-cost architecture, extended-gate biosensors based on the combination of a disposable sensing part and a reusable transducer have been widely utilized for the label-free electrical detection of chemical and biological species. Previous studies have demonstrated that sensitive and selective detection of ions and biomolecules can be achieved by controlled modification of the sensing part with an ion-selective membrane and receptors of interest. However, no systematic studies have been performed on the impact of the transducer on sensing performance. In this paper, we introduce the concept of a nanoscale field-effect transistor (FET) as a reusable and sensitive transducer for extended-gate biosensors. The capacitive effect from the external sensing part can degrade the sensing performance, but the nanoscale FET can reduce this effect. The nanoscale FET with a gate-all-around (GAA) structure exhibits a higher pH sensitivity than a commercially available FET, which is widely used in conventional extended-gate biosensors. A sensitivity reduction is observed for the commercial FET, whereas the pH sensitivity is insensitive to the area of the sensing region in the nanoscale FET, thus allowing the scaling of the detection area. Our analysis based on a capacitive model suggests that the high pH sensitivity in the compact sensing area originates from the small input capacitance of the nanoscale FET transducer. Moreover, a decrease in the nanowire width of the GAA FET leads to an improvement in the pH sensitivity. The extended-gate approach with the nanoscale FET-based transduction can pave the way for a highly sensitive analysis of chemical and biological species with a small sample volume.-
dc.languageEnglish-
dc.publisherAMER CHEMICAL SOC-
dc.titleNanoscale FET-Based Transduction toward Sensitive Extended-Gate Biosensors-
dc.typeArticle-
dc.identifier.wosid000473827800033-
dc.identifier.scopusid2-s2.0-85067938542-
dc.type.rimsART-
dc.citation.volume4-
dc.citation.issue6-
dc.citation.beginningpage1724-
dc.citation.endingpage1729-
dc.citation.publicationnameACS SENSORS-
dc.identifier.doi10.1021/acssensors.9b00731-
dc.contributor.localauthorChoi, Yang-Kyu-
dc.contributor.nonIdAuthorKwon, Jae-
dc.contributor.nonIdAuthorPark, Jun-Young-
dc.contributor.nonIdAuthorAhn, Jae-Hyuk-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorField-effect transistor-
dc.subject.keywordAuthornanoscale transducer-
dc.subject.keywordAuthorextended gate-
dc.subject.keywordAuthorchemical and biological sensor-
dc.subject.keywordAuthorpH sensor-
dc.subject.keywordAuthorsmall volume analysis-
dc.subject.keywordPlusFIELD-EFFECT-TRANSISTOR-
dc.subject.keywordPlusLABEL-FREE-
dc.subject.keywordPlusSILICON-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusNANOISFET-
dc.subject.keywordPlusSENSOR-
dc.subject.keywordPlusACID-
Appears in Collection
EE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 25 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0