dc.description.abstractRecently, a novel stress sensor, which utilizes the elasto-magnetic (EM) effect of ferromagnetic materials, has been developed to measure stress in steel cables and wires. In this study, the effectiveness of this EM based stress sensors for monitoring of the cable tension force of a real scale cable-stayed bridge was investigated. Two EM stress sensors were installed on two selected multi-strand cables in Hwa-Myung Bridge, Busan, South Korea. Conventional lift-off test was conducted to obtain reference cable tension forces of two test cables. The reference forces were used to calibrate and validate cable tension force measurements from the EM sensors. Tension force variations of two test cables during the second tensioning work on Hwa-Myung Bridge were monitored using the EM sensors. Numerical simulations were conducted to compare and verify the monitoring results. Based on the results, the effectiveness of EM sensors for accurate field monitoring of the cable tension force of cable-stayed bridge is discussed.-
dc.languageEnglish-
dc.publisherTECHNO-PRESS-
dc.subjectFREQUENCIES-
dc.titleField application of elasto-magnetic stress sensors for monitoring of cable tension force in cable-stayed bridges-
dc.typeArticle-
dc.identifier.wosid000324879200015-
dc.identifier.scopusid2-s2.0-84886942678-
dc.type.rimsART-
dc.citation.volume12-
dc.citation.issue3-4-
dc.citation.beginningpage465-
dc.citation.endingpage482-
dc.citation.publicationnameSMART STRUCTURES AND SYSTEMS-
dc.contributor.localauthorJung, Hyung-Jo-
dc.contributor.nonIdAuthorYim, Jinsuk-
dc.contributor.nonIdAuthorWang, Ming L.-
dc.contributor.nonIdAuthorShin, Sung Woo-
dc.contributor.nonIdAuthorYun, Chung-Bang-
dc.contributor.nonIdAuthorKim, Jeong-Tae-
dc.contributor.nonIdAuthorEem, Seung-Hyun-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorstress sensing-
dc.subject.keywordAuthorelasto-magnetic sensor-
dc.subject.keywordAuthorcable tension force monitoring-
dc.subject.keywordAuthorcable-stayed bridge-
dc.subject.keywordAuthorstructural health monitoring-
dc.subject.keywordPlusFREQUENCIES-
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 50 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0