Dynamic Simulation of the Water-steam System in Once-through Boilers - Sub-critical Power Boiler Case -관류보일러 물-증기 계통의 동적 시뮬레이션- 아임계 동력보일러 사례 -

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 1270
  • Download : 0
The dynamics of a water-steam system in a once-through boiler was simulated based on the physics-based modeling approach, representing the system in response to large load change or scale disturbance simulations. The modeling considered the mass, energy conservation, and momentum equation in the water pipe and the focus was limited to the sub-critical pressure region. An evaporator tube modeling was validated against the reference data. A simplified boiler system consisting of economizer, evaporator, and superheater was constructed to match a 500 MW power boiler. The dynamic response of the system following a disturbance was discussed along with the quantitative response characteristics. The dynamic response of the boiler system was further evaluated by checking the case of an off-design point operation of the feedwater-to-fuel supply ratio. The results re-emphasized the significance of controlling the feedwater-to-fuel supply ratio and additional design requirements of the water-steam separator and spray attemperator.
Publisher
KOREAN SOC MECHANICAL ENGINEERS
Issue Date
2017-05
Language
Korean
Article Type
Article
Citation

TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS B, v.41, no.5, pp.353 - 363

ISSN
1226-4881
DOI
10.3795/KSME-B.2017.41.5.353
URI
http://hdl.handle.net/10203/226158
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0