High-speed time-resolved laser-scanning microscopy using the line-to-pixel referencing method

Cited 6 time in webofscience Cited 0 time in scopus
  • Hit : 1207
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorRyu, Jiheunko
dc.contributor.authorKim, Jayulko
dc.contributor.authorKim, Hyunjunko
dc.contributor.authorJeong, Jae Heonko
dc.contributor.authorLee, Hak-Junko
dc.contributor.authorYoo, Hongkiko
dc.contributor.authorGweon, Dae-Gabko
dc.date.accessioned2017-01-23T02:57:04Z-
dc.date.available2017-01-23T02:57:04Z-
dc.date.created2016-12-19-
dc.date.created2016-12-19-
dc.date.created2016-12-19-
dc.date.created2016-12-19-
dc.date.issued2016-11-
dc.identifier.citationAPPLIED OPTICS, v.55, no.32, pp.9033 - 9041-
dc.identifier.issn1559-128X-
dc.identifier.urihttp://hdl.handle.net/10203/220202-
dc.description.abstractFluorescence lifetime imaging microscopy (FLIM) is a powerful technique to visualize photophysical characteristics of biological targets. However, conventional FLIM methods have some limitations that restrict obtaining high-precision images in real time. Here, we propose a high-speed time-resolved laser-scanning microscopy by incorporating a novel line-to-pixel referencing method into the previously suggested analog mean-delay (AMD) method. The AMD method dramatically enhances the photon accumulation speed for achieving the certain precision compared to the time-correlated single-photon counting (TCSPC) method while maintaining high photon efficiency. However, its imaging pixel rate can still be restricted by the rearm time of the digitizer when it is triggered by laser pulses. With our line-to-pixel referencing method, the pulse train repeats faster than the trigger rearm time can be utilized by generating a line trigger, which is phase-locked with only the first pulse in each horizontal line composing an image. Our proposed method has been tested with a pulsed laser with 40 MHz repetition rate and a commercial digitizer with a 500 ns trigger rearm time, and a frame rate of 3.73 fps with a pixel rate of 3.91 MHz was accomplished while maintaining the measurement precision under 20 ps. (C) 2016 Optical Society of America-
dc.languageEnglish-
dc.publisherOPTICAL SOC AMER-
dc.titleHigh-speed time-resolved laser-scanning microscopy using the line-to-pixel referencing method-
dc.typeArticle-
dc.identifier.wosid000387763900010-
dc.identifier.scopusid2-s2.0-84995495847-
dc.type.rimsART-
dc.citation.volume55-
dc.citation.issue32-
dc.citation.beginningpage9033-
dc.citation.endingpage9041-
dc.citation.publicationnameAPPLIED OPTICS-
dc.identifier.doi10.1364/AO.55.009033-
dc.contributor.localauthorYoo, Hongki-
dc.contributor.localauthorGweon, Dae-Gab-
dc.contributor.nonIdAuthorKim, Jayul-
dc.contributor.nonIdAuthorKim, Hyunjun-
dc.description.isOpenAccessN-
dc.type.journalArticleArticle-
dc.subject.keywordPlusLIFETIME IMAGING MICROSCOPY-
dc.subject.keywordPlusMEAN-DELAY METHOD-
dc.subject.keywordPlusFLUORESCENCE LIFETIME-
dc.subject.keywordPlusFLIM-
dc.subject.keywordPlusCELL-
dc.subject.keywordPlusPRECISION-
Appears in Collection
ME-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 6 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0