국내 옹벽의 유사정적 내진설계기준 개선방향에 대한 고찰A Discussion on the Improvement of Pseudo-Static Seismic Design Criteria of Retaining Wall in Domestic

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 497
  • Download : 0
This paper reviews the current seismic design code and research for dynamic earth pressure on retaining structures. Domestic design codes do not clearly define the estimation of dynamic earth pressure and give different comments for seismic coefficient, wall inertia and distribution of dynamic earth pressure using Mononobe-Okabe method. AASHTO has been revised reflecting current research and aims for effective seismic design. Various design codes are analyzed to compare their performance and economic efficiency. The results are used to make improvement of current domestic seismic design code. Further, it is concluded that the experimental investigation is also needed to verify and improve domestic seismic code for dynamic earth pressure.
Publisher
한국지진공학회
Issue Date
2015-03
Language
Korean
Citation

한국지진공학회논문집, v.19, no.2, pp.45 - 53

ISSN
1226-525X
URI
http://hdl.handle.net/10203/203571
Appears in Collection
CE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0