Accurate Dead-Time Control for Synchronous Buck Converter With Fast Error Sensing Circuits

Cited 20 time in webofscience Cited 24 time in scopus
  • Hit : 532
  • Download : 0
Dead-time controls for synchronous buck converter are challenging due to the difficulties in accurate sensing and processing the on/off dead-time errors. For the control of dead-times, an integral feedback control using switched capacitors and a fast timing sensing circuit composed of MOSFET differential amplifiers and switched current sources are proposed. Experiments for a 3.3 V input, 1.5 V-0.3 A output converter demonstrated 1.3 similar to 4.6% efficiency improvement over a wide load current range.
Publisher
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
Issue Date
2013-11
Language
English
Article Type
Article
Keywords

DC-DC CONVERTERS

Citation

IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-REGULAR PAPERS, v.60, no.11, pp.3080 - 3089

ISSN
1549-8328
DOI
10.1109/TCSI.2013.2252451