Improving image accuracy of region-of-interest in cone-beam CT using prior image

Cited 5 time in webofscience Cited 0 time in scopus
  • Hit : 984
  • Download : 489
In diagnostic follow-ups of diseases, such as calcium scoring in kidney or fat content assessment in liver using repeated CT scans, quantitatively accurate and consistent CT values are desirable at a low cost of radiation dose to the patient. Region-of-interest (ROI) imaging technique is considered a reasonable dose reduction method in CT scans for its shielding geometry outside the ROI. However, image artifacts in the reconstructed images caused by missing data outside the ROI may degrade overall image quality and, more importantly, can decrease image accuracy of the ROI substantially. In this study, we propose a method to increase image accuracy of the ROI and to reduce imaging radiation dose via utilizing the outside ROI data from prior scans in the repeated CT applications. We performed both numerical and experimental studies to validate our proposed method. In a numerical study, we used an XCAT phantom with its liver and stomach changing their sizes from one scan to another. Image accuracy of the liver has been improved as the error decreased from 44.4 HU to -0.1 HU by the proposed method, compared to an existing method of data extrapolation to compensate for the missing data outside the ROI. Repeated cone-beam CT (CBCT) images of a patient who went through daily CBCT scans for radiation therapy were also used to demonstrate the performance of the proposed method experimentally. The results showed improved image accuracy inside the ROI. The magnitude of error decreased from -73.2 HU to 18 HU, and effectively reduced image artifacts throughout the entire image.
Publisher
MULTIMED INC
Issue Date
2014
Language
English
Article Type
Article
Keywords

TUBE CURRENT MODULATION; COMPUTED-TOMOGRAPHY; MUTUAL-INFORMATION; DOSE REDUCTION; TRUNCATED PROJECTIONS; LIMITED FIELD; RECONSTRUCTION; VIEW; PHANTOM; SCAN

Citation

JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, v.15, no.2, pp.252 - 261

ISSN
1526-9914
URI
http://hdl.handle.net/10203/187239
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
82958.pdf(1.24 MB)Download
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 5 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0