Evaluation of maximum-likelihood position estimation with Poisson and Gaussian noise models in a small gamma camera

Cited 15 time in webofscience Cited 0 time in scopus
  • Hit : 914
  • Download : 1220
DC FieldValueLanguage
dc.contributor.authorChung, YHko
dc.contributor.authorChoi, Yko
dc.contributor.authorSong, TYko
dc.contributor.authorJung, JHko
dc.contributor.authorCho, Gyuseongko
dc.contributor.authorChoe, YSko
dc.contributor.authorLee, KHko
dc.contributor.authorKim, SEko
dc.contributor.authorKim, BTko
dc.date.accessioned2007-10-18T01:59:01Z-
dc.date.available2007-10-18T01:59:01Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2004-02-
dc.identifier.citationIEEE TRANSACTIONS ON NUCLEAR SCIENCE, v.51, pp.101 - 104-
dc.identifier.issn0018-9499-
dc.identifier.urihttp://hdl.handle.net/10203/1733-
dc.description.abstractIt has been reported that maximum-likelihood position estimation (MLPE) algorithms offer advantages of improved spatial resolution and linearity over conventional Anger algorithm in gamma cameras. While the fluctuation of photon measurements is more accurately described by Poisson than Gaussian distribution model, the likelihood function of a scintillation event assumed to be Gaussian could be more easily implemented and might provide more consistent outcomes than Poisson-based MLPE. The purpose of this study is to evaluate the performances of the noise models, Poisson and Gaussian, in MLPE for the localization of photons in a small gamma camera (SGC) using NaI(Tl) plate and PSPMT. The SGC consisted of a single NaI(Tl) crystal, 10 cm in diameter and 6 mm thick, optically coupled to a PSPMT (Hamamatsu R3292-07). The PSPMT was read out using a resistive charge divider, which multiplexes 28(X) by 28(Y) cross wire anodes into four channels. Poisson and Gaussian-based MLPE methods have been implemented using experimentally measured detector response functions (DRF). The averaged intrinsic spatial resolutions were 3.14, 3.09, and 2.88 mm, the integral uniformities were 15.3%, 12.3%, and 11.4%, and the averaged linearities were 0.75, 0.33, and 0.22 mm for Anger logic, Poisson, and Gaussian-based MLPE, respectively. MLPEs considerably improved linearity and uniformity compared to Anger logic. Gaussian-based MLPE, which is easy to implement, allowed to obtain better linearity and uniformity performances than the Poisson-based MLPE.-
dc.languageEnglish-
dc.language.isoen_USen
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectSCINTILLATION CAMERAS-
dc.subjectPSPMT-
dc.titleEvaluation of maximum-likelihood position estimation with Poisson and Gaussian noise models in a small gamma camera-
dc.typeArticle-
dc.identifier.wosid000220883100018-
dc.identifier.scopusid2-s2.0-2342637068-
dc.type.rimsART-
dc.citation.volume51-
dc.citation.beginningpage101-
dc.citation.endingpage104-
dc.citation.publicationnameIEEE TRANSACTIONS ON NUCLEAR SCIENCE-
dc.embargo.liftdate9999-12-31-
dc.embargo.terms9999-12-31-
dc.contributor.localauthorCho, Gyuseong-
dc.contributor.nonIdAuthorChung, YH-
dc.contributor.nonIdAuthorChoi, Y-
dc.contributor.nonIdAuthorSong, TY-
dc.contributor.nonIdAuthorJung, JH-
dc.contributor.nonIdAuthorChoe, YS-
dc.contributor.nonIdAuthorLee, KH-
dc.contributor.nonIdAuthorKim, SE-
dc.contributor.nonIdAuthorKim, BT-
dc.type.journalArticleArticle-
dc.subject.keywordAuthorposition measurement-
dc.subject.keywordAuthorposition sensitive PMT-
dc.subject.keywordAuthorsmall gamma camera-
dc.subject.keywordPlusSCINTILLATION CAMERAS-
dc.subject.keywordPlusPSPMT-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 15 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0