입력전류센서 없는 단상전력변환기의 역률개선 기법Power Factor Correction Method without Input Current Sensor

Cited 0 time in webofscience Cited 0 time in scopus
  • Hit : 535
  • Download : 0
New simple control method of power factor correcting(PFC) boost convertor without instantaneous measurement of input current is proposed. Using the averaged model, the power factor correction scheme is presented. With the measurements of input voltage and output voltage, the control signal is generated to make the shape of the line current same as the input voltage. The validity of the controller is verified through the computer simulations.
Publisher
KIEE
Issue Date
1996-07
Language
KOR
Citation

Proceeding of '96 KIEE Summer Conference, pp.564 - 566

URI
http://hdl.handle.net/10203/125023
Appears in Collection
EE-Conference Papers(학술회의논문)
Files in This Item
There are no files associated with this item.

qr_code

  • mendeley