Deconvolution of gamma-ray spectra obtained with NAI(Tl) detector in a water tank

Cited 7 time in webofscience Cited 0 time in scopus
  • Hit : 646
  • Download : 0
DC FieldValueLanguage
dc.contributor.authorKang, Bo-Sunko
dc.contributor.authorRahman, M. Sohelurko
dc.contributor.authorCho, Gyuseongko
dc.date.accessioned2013-03-12T02:55:55Z-
dc.date.available2013-03-12T02:55:55Z-
dc.date.created2012-02-06-
dc.date.created2012-02-06-
dc.date.issued2009-07-
dc.identifier.citationRADIATION PROTECTION DOSIMETRY, v.135, no.3, pp.203 - 210-
dc.identifier.issn0144-8420-
dc.identifier.urihttp://hdl.handle.net/10203/101139-
dc.description.abstractMaximum-likelihood fitting by the expectation maximisation deconvolution method is presented to analyse gamma-ray spectra recorded using an NaI(Tl) detector for a water monitoring system. The applicability of the method was tested by deconvolving measured spectra taken using an industry standard 3 ' x 3 ' cylindrical NaI(Tl) detector in a model water tank with several calibration sources. The results show significant removal of the Compton continuum counts and efficient transfer of the counts into the corresponding photo-peaks. The peak-to-total count ratio and the number of counts in the photo-peaks in the deconvolved spectra increased approximately 4.67 and 5.29 times, respectively, compared with those of measured spectra taken using an NaI(Tl) scintillation detector in the case of (137)Cs.-
dc.languageEnglish-
dc.publisherOXFORD UNIV PRESS-
dc.subjectSCINTILLATION DETECTORS-
dc.subjectMAXIMUM-LIKELIHOOD-
dc.subjectRESPONSE MATRIX-
dc.subjectRADIOACTIVITY-
dc.subjectSTATISTICS-
dc.subjectSIMULATION-
dc.titleDeconvolution of gamma-ray spectra obtained with NAI(Tl) detector in a water tank-
dc.typeArticle-
dc.identifier.wosid000267889600006-
dc.identifier.scopusid2-s2.0-67651102488-
dc.type.rimsART-
dc.citation.volume135-
dc.citation.issue3-
dc.citation.beginningpage203-
dc.citation.endingpage210-
dc.citation.publicationnameRADIATION PROTECTION DOSIMETRY-
dc.identifier.doi10.1093/rpd/ncp102-
dc.contributor.localauthorCho, Gyuseong-
dc.type.journalArticleArticle-
dc.subject.keywordPlusSCINTILLATION DETECTORS-
dc.subject.keywordPlusMAXIMUM-LIKELIHOOD-
dc.subject.keywordPlusRESPONSE MATRIX-
dc.subject.keywordPlusRADIOACTIVITY-
dc.subject.keywordPlusSTATISTICS-
dc.subject.keywordPlusSIMULATION-
Appears in Collection
NE-Journal Papers(저널논문)
Files in This Item
There are no files associated with this item.
This item is cited by other documents in WoS
⊙ Detail Information in WoSⓡ Click to see webofscience_button
⊙ Cited 7 items in WoS Click to see citing articles in records_button

qr_code

  • mendeley

    citeulike


rss_1.0 rss_2.0 atom_1.0